Features:

  • Large grain holding capacity allows for higher bushels per hour to consistently achieve maximum drying. Long retention times result in better grain quality

  • High/Low fire cycling helps to maintain a uniform plenum temperature

  • 14" wide columns hold the maximum amount of grain while minimizing the difference from the inside to the outside of the column

  • Each plenum chamber also has an air mixing chamber to thoroughly mix the air and heat, and to shield the grain columns from direct contact with the burner infra red waves

  • Multiple heat zones in two-fan and larger model dryers put the hottest air on the highest moisture grain

  • "Star-Fire Burners" provide optimal heat delivery efficiency and a lower cost of operation. LP units feature patented "Blue Burn" optimizer

  • Optimized airflow to 80 cfM per bushel sized to match the basket to achieve consistent airflow on all models

  • Air mixers mixing vanes eliminate "hot spots" and create a uniform plenum temperature

  • Adjustable flow gates allow customized control of grain volume in each column for improved quality and more even drying when grain quality is poor and there are a lot of fines present

  • Related Products
    and Accessories:

    X-Stream Series Dryers

    Fans and Heaters

    Vision Controls for Portable Dryers



    > Home > Commercial > Drying & Conditioning > Portable Dryers

    Portable Grain Dryers

    Portable Dryers

    GSI offers the most technologically advanced and reliable dryers on the market today. We also have the widest selection of dryer models, suitable for a wide variety of applications. All GSI dryers feature easy-to-use and state-of-the-art controls, heavy-duty galvanized steel construction, and industrial grade electrical components. GSI dryers can help solve even the most complex grain conditioning problems.


    Fans and Heaters

    Fans and Heaters
    GSI’s high efficiency one-piece fan and heater unit provides optimal heated air flow for all dryer applications and utilizes only 1725 rpm low-speed and low-noise fans which are more energy efficient than centrifugal fans in this application. All units feature fiberglass reinforced polypropylene fan blades with a very low starting load, high air flow across a wide static pressure range, precise balance and quiet operation.

    Ten different fan configurations are available. An electronic ignition system monitors the burner and a view window provides easy observation. The Optimizer Blue Burn System is standard on all LP models and assures energy efficient operation.


    Rear Discharge

    Rear Discharge Auto-Shutdown
    A 2’ discharge extension with manual grain sampler is standard equipment. An automatic discharge shutdown operates off of a hinged lid switch at the rear discharge. It is activated when grain overfills the discharge auger and forces the lid to open.



    Clean-Out Doors

    Clean-Out Made Easy
    Large plenum clean-out doors make for easy access to the unload auger and metering rolls.

    Inside metering and unload auger access panels lift out of the way without tools to better accommodate service and maintenance needs.

    Sealing strips reduce air pressure and heat loss into the unload chamber.


    Dura-Edge Auger Flighting

    8" DURA-EDGE® Auger Flighting
    All augers feature the new DURA-EDGE® 8” diameter flighting with 1/4” ribbon. The DURA-EDGE® flighting has an outside edge that is 30% thicker than regular flighting. This contributes to the product’s long life and dependability.




    Sidewall Screens

    Three-Piece Sidewall Screens
    GSI’s three-piece sidewall panels allow the top angle section alone, the top angle and side sections, or all of the exterior screens including the bottom angle section to optionally be stainless steel. This allows for economical protection against rust and corrosion where needed based on the size of the dryer and the type of usage it will experience. All fastening hardware are also stainless steel to eliminate future corrosion.


    Access Ladders

    Access Ladders
    GSI ladders feature heavy-duty construction and slip-resistant patterns to give extra grip in wet conditions. Our attention to detail and quality design gives GSI a solid foothold in the grain drying business.



    Vision Dryer Controls

    Vision Dryer Controls
    The GSI Vision dryer control system features a wide array of settings that offers unparalleled options and control. Boasting a 10.4" TFT color touch screen with easy-to-use controls, the Vision can be remote-mounted, via a simple seven wire harness, up to 1000 feet away from the dryer.

    The Vision system features a low voltage safety circuit and a safety disconnect on every dryer. Each safety is monitored individually and its status displayed on-screen. With no moving parts – timers, time delays, thermostats, etc. – the Vision system is less prone to wear-and-tear that leads to costly repairs and downtime. Plenum and grain temperatures can be modified on-screen. You can also change from High/Low to On/Off fire mode which allows plenum operation down to 5 degrees above ambient with a simple software switch.  MORE


    Specifications

    100 SERIES DRYER    
     
    108
    112
    114
    116
    118
    120
    122
    126
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15% Staged Batch
    165 BPH
    220 BPH
    260 BPH
    280 BPH
    320 BPH
    360 BPH
    390 BPH
    455 BPH
    Dry and Cool 20% to 15% Staged Batch
    220 BPH
    290 BPH
    340 BPH
    370 BPH
    430 BPH
    475 BPH
    520 BPH
    605 BPH
    Full Heat 30% to 15%2
    190 BPH
    255 BPH
    300 BPH
    320 BPH
    380 BPH
    415 BPH
    460 BPH
    540 BPH
    Full Heat 25% to 15%2
    260 BPH
    345 BPH
    405 BPH
    440 BPH
    505 BPH
    560 BPH
    610 BPH
    715 BPH
    Full Heat 20% to 15%2
    420 BPH
    560 BPH
    650 BPH
    710 BPH
    815 BPH
    905 BPH
    990 BPH
    1155 BPH
    Basic Construction
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
     
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    Grain Columns
    14" x 8' Long
    14" x 12' Long
    14" x 14' Long
    14" x 16' Long
    14" x 18' Long
    14" x 20' Long
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    219 BU
    327 BU
    381 BU
    436 BU
    490 BU
    544 BU
    599 BU
    708 BU
    Grain Column Holding Capacity
    190 BU
    282 BU
    329 BU
    376 BU
    423 BU
    470 BU
    517 BU
    611 BU
    Top Auger (Loading)
    8' Flight
    8' Flight
    8' Flight
    8' Flight
    8' Flight
    8' Flight
    8' Flight
    8' Flight
     
    2 HP
    2 HP
    3 HP
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Capacity
    3800 BPH
    3800 BPH
    3800 BPH
    3800 BPH
    3800 BPH
    3800 BPH
    3800 BPH
    3800 BPH
    Bottom Auger (Unloading)
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
     
    1.5 HP
    1.5 HP
    3 HP
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    1125 BPH
    1680 BPH
    1960 BPH
    2240 BPH
    2520 BPH
    2800 BPH
    3080 BPH
    3640 BPH
    Transport Length (Hitch to Discharge Auger)
    17'2"
    21'2"
    23'2"
    25'2"
    27'2"
    29'2"
    31'2"
    35'2"
    Transport Width
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    Transport Height3
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    Transport Weight (approx.) (Less Transport Kit)
    5,000 lbs.
    6,300 lbs.
    7,000 lbs.
    7,500 lbs.
    8,000 lbs.
    8,700 lbs.
    9,000 lbs.
    11,000 lbs.
    Installed Length
    15'2"
    19'2"
    21'2"
    23'2"
    25'2"
    27'2"
    29'2"
    33'2"
    Installed Width
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    Installed Height (Excluding Foundation Supports)
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    Fan 1 PH
    10-12 HP, 36"
    10-16 HP, 36"
    10-16 HP, 40"
    10-16 HP, 40"
    N/A
    N/A
    N/A
    N/A
    Fan 3 PH
    10-12 HP, 36"
    15 HP, 36"
    15 HP, 40"
    15 HP, 40"
    20 HP, 42"
    25 HP, 42"
    30 HP, 42"
    40 HP, 42"
    Heater (Max BTU)
    3.5 Mil. btu/hr
    4.5 Mil. btu/hr
    5.75 Mil. btu/hr
    5.75 Mil. btu/hr
    6.75 Mil. btu/hr
    7.5 Mil. btu/hr
    8.75 Mil. btu/hr
    10.25 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    69/131
    90/152
    103/165
    113/175
    N/A
    N/A
    N/A
    N/A
    Three Phase, 208 V. - Min/Max Amps
    55/105
    68/119
    75/140
    88/153
    102/167
    134/230
    148/244
    182/279
    Three Phase, 240 V. - Min/Max Amps
    46/86
    55/95
    60/112
    70/122
    84/136
    109/187
    119/197
    155/233
    Three Phase, 380 V. - Min/Max Amps
    25/51
    36/61
    39/70
    46/77
    53/84
    69/119
    76/126
    94/144
    Three Phase, 480 V. - Min/Max Amps
    26/46
    30/50
    33/59
    38/64
    45/71
    57/96
    62/101
    80/119
    Three Phase, 575 V. - Min/Max Amps
    23/39
    26/42
    28/48
    32/52
    36/57
    47/79
    51/83
    66/98

     

    1100 SERIES MODELS    
     
    1108
    1112
    1114
    1116
    1118
    1120
    1122
    1126
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15% Staged Batch
    165 BPH
    220 BPH
    260 BPH
    280 BPH
    320 BPH
    360 BPH
    390 BPH
    455 BPH
    Dry and Cool 20% to 15% Staged Batch
    220 BPH
    290 BPH
    340 BPH
    370 BPH
    430 BPH
    475 BPH
    520 BPH
    605 BPH
    Full Heat 30% to 15%2
    190 BPH
    255 BPH
    300 BPH
    320 BPH
    380 BPH
    415 BPH
    460 BPH
    540 BPH
    Full Heat 25% to 15%2
    260 BPH
    345 BPH
    405 BPH
    440 BPH
    505 BPH
    560 BPH
    610 BPH
    715 BPH
    Full Heat 20% to 15%2
    420 BPH
    560 BPH
    650 BPH
    710 BPH
    815 BPH
    905 BPH
    990 BPH
    1,155 BPH
    Basic Construction
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
     
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    1 Stage
    Grain Columns
    14" x 8' Long
    14" x 12' Long
    14" x 14' Long
    14" x 16' Long
    14" x 18' Long
    14" x 20' Long
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    219 BU
    327 BU
    381 BU
    436 BU
    490 BU
    544 BU
    599 BU
    708 BU
    Grain Column Holding Capacity
    190 BU
    282 BU
    329 BU
    376 BU
    423 BU
    470 BU
    517 BU
    611 BU
    Top Auger (Loading)
    8" Flight
    8" Flight
    8" Flight
    8" Flight
    8" Flight
    8" Flight
    8" Flight
    8" Flight
     
    2 HP
    2 HP
    3 HP
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
    8" Flight
    10" Tube
     
    1.5 HP
    1.5 HP
    3 HP
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    1,125 BPH
    1,680 BPH
    1,960 BPH
    2,240 BPH
    2,520 BPH
    2,800 BPH
    3,080 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    17'2"
    21'2"
    23'2"
    25'2"
    27'2"
    29'2"
    31'2"
    35'2"
    Transport Width
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    Transport Height3
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    13'5"
    (11'9")
    Transport Weight (approx.) (Less Transport Kit)
    5,200 lbs.
    6,300 lbs.
    7,000 lbs.
    7,500 lbs.
    8,000 lbs.
    8,700 lbs.
    9,500 lbs.
    11,000 lbs.
    Installed Length
    15'2"
    19'2"
    21'2"
    23'2"
    25'2"
    27'2"
    29'2"
    33'2"
    Installed Width
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    8'
    Installed Height (Excluding Foundation Supports)
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    Fan 1 PH
    10-16 HP, 36"
    10-16 HP, 36"
    10-16 HP, 40"
    10-16 HP, 40"
    N/A
    N/A
    N/A
    N/A
    Fan 3 PH
    10-16 HP, 36"
    15 HP, 36"
    15 HP, 40"
    15 HP, 40"
    20 HP, 42"
    25 HP, 42"
    30 HP, 42"
    40 HP, 42"
    Heater (Max BTU)
    3.5 Mil. btu/hr
    4.5 Mil. btu/hr
    5.75 Mil. btu/hr
    5.75 Mil. btu/hr
    6.75 Mil. btu/hr
    7.5 Mil. btu/hr
    8.75 Mil. btu/hr
    10.25 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    101/122
    101/156
    109/164
    124/179
    N/A
    N/A
    N/A
    N/A
    Three Phase, 208 V. - Min/Max Amps
    57/95
    57/95
    64/115
    77/127
    88/138
    117/193
    128/204
    167/244
    Three Phase, 230 V. - Min/Max Amps
    53/83
    53/88
    60/108
    71/120
    81/130
    107/178
    117/188
    157/228
    Three Phase, 460 V. - Min/Max Amps
    29/41
    29/44
    32/54
    38/60
    43/65
    56/89
    61/94
    81/114
    Three Phase, 575 V. - Min/Max Amps
    25/36
    25/36
    28/45
    33/50
    36/54
    46/73
    50/77
    67/94

     

    1200 SERIES MODELS    
     
    1214
    1216
    1218
    1220
    1222
    1226
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15%
    250 BPH
    290 BPH
    315 BPH
    345 BPH
    395 BPH
    450 BPH
    Dry and Cool 20% to 15%
    400 BPH
    465 BPH
    505 BPH
    560 BPH
    640 BPH
    725 BPH
    Full Heat 30% to 15%2
    335 BPH
    380 BPH
    415 BPH
    436 BPH
    485 BPH
    545 BPH
    Full Heat 25% to 15%2
    415 BPH
    475 BPH
    520 BPH
    590 BPH
    650 BPH
    730 BPH
    Full Heat 20% to 15%2
    680 BPH
    765 BPH
    840 BPH
    950 BPH
    1,055 BPH
    1,180 BPH
    Basic Construction
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
     
    2 Stages
    2 Stages
    2 Stages
    2 Stages
    2 Stages
    2 Stages
    Grain Columns
    14" x 14' Long
    14" x 16' Long
    14" x 18' Long
    14" x 20' Long
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    381 BU
    436 BU
    490 BU
    544 BU
    599 BU
    708 BU
    Grain Column Holding Capacity
    329 BU
    376 BU
    423 BU
    470 BU
    517 BU
    611 BU
    Top Auger (Loading)
    8", 5 HP
    8", 5 HP
    8", 5 HP
    8", 7.5 HP
    8", 7.5 HP
    8", 10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
     
    5 HP
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    1,960 BPH
    2,240 BPH
    2,520 BPH
    2,800 BPH
    3,080 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    23'2"
    25'2"
    27'2"
    29'2"
    31'2"
    35'2"
    Transport Width
    8'
    8'
    8'
    8'
    8'
    8'
    Transport Height3
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    13'5"(11'9")
    13'5" (11'9")
    Transport Weight (approx.) (Less Transport Kit)
    7,600 lbs.
    8,200 lbs.
    9,000 lbs.
    9,800 lbs.
    10,500 lbs.
    12,000 lbs.
    Installed Length
    21'2"
    23'2"
    25'2"
    27'2"
    29'2"
    33'2"
    Installed Width
    8'
    8'
    8'
    8'
    8'
    8'
    Installed Height (Excluding Foundation Supports)
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    Fans 1 PH
    1@10-12 HP, 36"
    1@15 HP, 36"
    1@15 HP, 36"
    1@15 HP, 40"
    N/A
    N/A
     
    1@10-12 HP, 26"
    1@10-12 HP, 26"
    1@10-12 HP, 26"
    1@10-12 HP, 28"
    N/A
    N/A
    Fans 3 PH
    1@10-12 HP, 36"
    1@15 HP, 36"
    1@15 HP, 36"
    1@15 HP, 40"
    1@20 HP, 42"
    1@25 HP, 42"
     
    1@10-12 HP, 26"
    1@10-12 HP, 26"
    1@10-12 HP, 26"
    1@10-12 HP, 28"
    1@10-12 HP, 28"
    1@10-12 HP, 28"
    Heaters (Max BTU)
    1@3.5 Mil. btu/hr
    1@4.5 Mil. btu/hr
    1@4.5 Mil. btu/hr
    1@5.5 Mil. btu/hr
    1@6.75 Mil. btu/hr
    1@7.5 Mil. btu/hr
     
    1@2.7 Mil. btu/hr
    1@2.7 Mil. btu/hr
    1@2.7 Mil. btu/hr
    1@3.0 Mil. btu/hr
    1@3.0 Mil. btu/hr
    1@3.0 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    157/212
    177/232
    177/232
    191/246
    N/A
    N/A
    Three Phase, 208 V. - Min/Max Amps
    112/162
    112/162
    112/162
    125/202
    136/213
    164/240
    Three Phase, 230 V. - Min/Max Amps
    99/148
    104/153
    104/153
    116/187
    126/197
    154/225
    Three Phase, 460 V. - Min/Max Amps
    52/74
    55/76
    55/76
    61/93
    66/98
    80/112
    Three Phase, 575 V. - Min/Max Amps
    48/66
    49/66
    49/66
    54/81
    57/84
    68/95

     

    1200 S AND H-SERIES MODELS    
     
    1214S
    1218S
    1220S & 1220H*
    1222S & 1222H*
    1226S & 1226H*
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15% Staged Batch
    260 BPH
    345 BPH
    395 BPH
    430 BPH
    530 BPH
    Dry and Cool 20% to 15% Staged Batch
    360 BPH
    450 BPH
    520 BPH
    565 BPH
    700 BPH
    Dry and Cool 25% to 15%
    185 BPH
    240 BPH
    280 BPH
    300 BPH
    375 BPH
    Dry and Cool 20% to 15%
    300 BPH
    385 BPH
    445 BPH
    485 BPH
    600 BPH
    Full Heat 30% to 15%2
    305 BPH
    395 BPH
    455 BPH
    495 BPH
    620 BPH
    Full Heat 25% to 15%2
    410 BPH
    535 BPH
    615 BPH
    670 BPH
    820 BPH
    Full Heat 20% to 15%2
    675 BPH
    860 BPH
    990 BPH
    1,080 BPH
    1,330 BPH
    Basic Construction
    1 Module
    1 Module
    1 Module
    1 Module
    1 Module
     
    2 Stages
    2 Stages
    2 Stages
    2 Stages
    2 Stages
    Grain Columns
    14" x 14' Long
    14" x 18' Long
    14" x 20' Long
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    381 BU
    490 BU
    544 BU
    599 BU
    708 BU
    Grain Column Holding Capacity
    329 BU
    423 BU
    470 BU
    517 BU
    611 BU
    Top Auger (Loading)
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
     
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    1,960 BPH
    2,520 BPH
    2,800 BPH
    3,080 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    23'2"
    27'2"
    29'2"
    31'2"
    35'2"
    Transport Width
    8'
    8'
    8'
    8'
    8'
    Transport Height3
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    13'5"(11'9")
    13'5" (11'9")
    Transport Weight (approx.) (Less Transport Kit)
    9,500 lbs.
    11,500 lbs.
    14,500 lbs.
    15,500 lbs.
    18,500 lbs.
    Installed Length
    21'2"
    25'2"
    27'2"
    30'2"
    33'2"
    Installed Width
    8'8"
    8'8"
    8'8"
    8'8"
    8'8"
    Installed Height (Excluding Foundation Supports)
    14'6"
    14'6"
    14'6"
    14'6"
    14'6"
    Fans 1 PH
    2@10-12 HP, 28"
    2@10-12 HP, 36"
    2@15 HP, 36"
    2@15 HP, 36"
    N/A
    Fans 3 PH
    2@10-12 HP, 28"
    2@10-12 HP, 36"
    2@15 HP, 36"
    2@15 HP, 36"
    2@25 HP, 40"
    Heaters (Max BTU)
    2@3.0 Mil. btu/hr
    2@3.5 Mil. btu/hr
    2@4.5 Mil. btu/hr
    2@4.5 Mil. btu/hr
    2@6.75 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    157/212
    157/212
    211/266
    211/266
    N/A
    Three Phase, 208 V. - Min/Max Amps
    106/156
    106/144
    131/208
    131/208
    196/273
    Three Phase, 230 V. - Min/Max Amps
    99/148
    99/134
    121/192
    121/192
    183/254
    Three Phase, 460 V. - Min/Max Amps
    52/74
    52/68
    63/96
    63/96
    94/127
    Three Phase, 575 V. - Min/Max Amps
    48/66
    48/66
    54/81
    54/81
    77/104

    *Note: S-Series dryers are upgradable with additional modules while the H-Series is not.

     

    2300 SERIES MODELS    
     
    2314
    2318
    2320
    2322
    2326
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15%
    615 BPH
    770 BPH
    850 BPH
    930 BPH
    1,130 BPH
    Dry and Cool 20% to 15%
    995 BPH
    1,235 BPH
    1,375 BPH
    1,500 BPH
    1,835 BPH
    Full Heat 30% to 15%2
    670 BPH
    830 BPH
    925 BPH
    1,010 BPH
    1,200 BPH
    Full Heat 25% to 15%2
    900 BPH
    1,120 BPH
    1,245 BPH
    1,355 BPH
    1,670 BPH
    Full Heat 20% to 15%2
    1,455 BPH
    1,805 BPH
    2,010 BPH
    2,195 BPH
    2,700 BPH
    Basic Construction
    2 Modules
    2 Modules
    2 Modules
    2 Modules
    2 Modules
     
    4 Stages
    4 Stages
    4 Stages
    4 Stages
    4 Stages
    Grain Columns
    14" x 14' Long
    14" x 18' Long
    14" x 20' Long
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    731 BU
    940 BU
    1,044 BU
    1,149 BU
    1,304 BU
    Grain Column Holding Capacity
    679 BU
    873 BU
    970 BU
    1,067 BU
    1,261 BU
    Top Auger (Loading)
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
     
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    1,960 BPH
    2,520 BPH
    2,800 BPH
    3,080 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    23'2"
    27'2"
    29'2"
    31'2"
    35'2"
    Transport Width
    8'
    8'
    8'
    8'
    8'
    Transport Height3
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    13'5"(11'9")
    13'5" (11'9")
    Transport Weight (approx.) (Less Transport Kit)
    16,000 lbs.
    19,000 lbs.
    21,000 lbs.
    22,500 lbs.
    25,000 lbs.
    Installed Length
    23'10"
    27'10"
    29'10"
    31'10"
    35'10"
    Installed Width
    8'8"
    8'8"
    8'8"
    8'8"
    8'8"
    Installed Height (Excluding Foundation Supports)
    25'11"
    25'11"
    25'11"
    25'11"
    25'11"
    Fans 1 PH
    1@15 HP, 40"
    N/A
    N/A
    N/A
    N/A
    2@10-12 HP, 28"
    N/A
    N/A
    N/A
    N/A
    Fans 3 PH
    1@15 HP, 40"
    1@20 HP, 42"
    1@25 HP, 42"
    1@30 HP, 42"
    1@40?HP, 42"
     
    2@10-12 HP, 28"
    2@10-12 HP, 36"
    2@15 HP, 36"
    2@15 HP, 36"
    2@25 HP, 40"
    Heaters (Max BTU)
    1@5.5 Mil. btu/hr
    1@6.75 Mil. btu/hr
    1@7.5 Mil. btu/hr
    1@8.75 Mil. btu/hr
    1@10.75 Mil. btu/hr
     
    2@3.0 Mil. btu/hr
    2@3.5 Mil. btu/hr
    2@4.5 Mil. btu/hr
    2@4.5 Mil. btu/hr
    2@6.75 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    230/285
    N/A
    N/A
    N/A
    N/A
    Three Phase, 208 V. - Min/Max Amps
    147/197
    158/208
    199/275
    199/275
    302/379
    Three Phase, 230 V. - Min/Max Amps
    137/186
    135/184
    183/254
    183/254
    281/352
    Three Phase, 460 V. - Min/Max Amps
    71/93
    70/92
    94/127
    99/132
    143/176
    Three Phase, 575 V. - Min/Max Amps
    65/82
    68/86
    78/105
    82/109
    115/142

     

    2400 SERIES MODELS    
     
    2420
    2426
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15%
    850 BPH
    1,130 BPH
    Dry and Cool 20% to 15%
    1,375 BPH
    1,835 BPH
    Full Heat 30% to 15%2
    925 BPH
    1,200 BPH
    Full Heat 25% to 15%2
    1,245 BPH
    1,670 BPH
    Full Heat 20% to 15%2
    2,010 BPH
    2,700 BPH
    Basic Construction
    2 Modules
    2 Modules
     
    4 Stages
    4 Stages
    Grain Columns
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    1,044 BU
    1,340 BU
    Grain Column Holding Capacity
    970 BU
    1,261 BU
    Top Auger (Loading)
    7.5 HP
    10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    2,800 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    29'2"
    35'2"
    Transport Width
    8'
    8'
    Transport Height3
    13'5" (11'9")
    13'5" (11'9")
    Installed Length
    29'10"
    35-10
    Installed Width
    8'8"
    8'8"
    Installed Height (Excluding Foundation Supports)
    25'11"
    25'11"
    Fans 1 PH
    N/A
    N/A
    Fans 3 PH
    4@15 HP, 36"
    4@25 HP, 40"
    Heaters (Max BTU)
    4@4.5 Mil. btu/hr
    4@6.75 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    N/A
    N/A
    Three Phase, 230 V. - Min/Max Amps
    196 Amps
    308 Amps
    Three Phase, 380 V. - Min/Max Amps
    134 Amps
    199 Amps
    Three Phase, 460 V. - Min/Max Amps
    98 Amps
    154 Amps
    Three Phase, 575 V. - Min/Max Amps
    80 Amps
    124 Amps

     

    3400 SERIES MODELS    
     
    3414
    3418
    3420
    3422
    3426
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15%
    840 BPH
    1,035 BPH
    1,120 BPH
    1,250 BPH
    1,520 BPH
    Dry and Cool 20% to 15%
    1,340 BPH
    1,665 BPH
    1,800 BPH
    2,015 BPH
    2,445 BPH
    Full Heat 30% to 15%2
    1,000 BPH
    1,250 BPH
    1,400 BPH
    1,515 BPH
    1,825 BPH
    Full Heat 25% to 15%2
    1,355 BPH
    1,680 BPH
    1,825 BPH
    2,040 BPH
    2,475 BPH
    Full Heat 20% to 15%2
    2,190 BPH
    2,720 BPH
    2,950 BPH*
    3,300 BPH*
    4,000 BPH*
    Basic Construction
    3 Modules
    3 Modules
    3 Modules
    3 Modules
    3 Modules
     
    6 Stages
    6 Stages
    6 Stages
    6 Stages
    6 Stages
    Grain Columns
    14" x 14' Long
    14" x 18' Long
    14" x 20' Long
    14" x 22' Long
    14" x 26' Long
    Total Holding Capacity
    1,074 BU
    1,381 BU
    1,534 BU
    1,688 BU
    1,995 BU
    Grain Column Holding Capacity
    1,022 BU
    1,314 BU
    1,460 BU
    1,606 BU
    1,898 BU
    Top Auger (Loading)
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
    8" Flight/10" Tube
     
    5 HP
    5 HP
    7.5 HP
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    1,960 BPH
    2,520 BPH
    2,800 BPH
    3,080 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    23'2"
    27'2"
    29'2"
    31'2"
    35'2"
    Transport Width
    8
    8
    8
    8
    8
    Transport Height3
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    13'5" (11'9")
    Transport Weight (approx.) (Less Transport Kit)
    23,000 lbs.
    26,500 lbs.
    29,500 lbs.
    30,500 lbs.
    35,000 lbs.
    Installed Length
    23'10"
    27'10"
    29'10"
    31'10"
    35'10"
    Installed Width
    8-8
    8-8
    8-8
    8-8
    8-8
    Installed Height (Excluding Foundation Supports)
    37'3"
    37'3"
    37'3"
    37'3"
    37'3"
    Fans 1 PH
    2@15 HP, 40"
    N/A
    N/A
    N/A
    N/A
     
    2@10-12 HP, 28"
    N/A
    N/A
    N/A
    N/A
    Fans 3 PH
    2@15 HP, 40"
    2@20 HP, 42"
    2@25 HP, 42"
    2@30 HP, 42"
    2@40 HP, 42"
     
    2@10-12 HP, 28"
    2@10-12 HP, 36"
    2@15 HP, 36"
    2@15 HP, 36"
    2@25 HP, 40"
    Heaters (Max BTU)
    2@5.5 Mil. btu/hr
    2@6.75 Mil. btu/hr
    2@7.5 Mil. btu/hr
    2@8.75 Mil. btu/hr
    2@10.25 Mil. btu/hr
     
    2@3.0 Mil. btu/hr
    2@3.5 Mil. btu/hr
    2@4.5 Mil. btu/hr
    2@4.5 Mil. btu/hr
    2@6.75 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    303/358
    N/A
    N/A
    N/A
    N/A
    Three Phase, 208 V. - Min/Max Amps
    188/238
    210/260
    266/343
    266/343
    300/377
    Three Phase, 230 V. - Min/Max Amps
    175/224
    183/232
    245/316
    245/316
    279/350
    Three Phase, 460 V. - Min/Max Amps
    90/112
    94/116
    125/158
    135/168
    192/225
    Three Phase, 575 V. - Min/Max Amps
    81/98
    88/106
    103/130
    111/138
    154/181

    * Limited by Meter Roll maximum capacity.

     

    3600 SERIES MODELS    
     
    3620
    3626
    Drying Capacity, Shelled Corn1
    Dry and Cool 25% to 15%
    1,120 BPH
    1,520 BPH
    Dry and Cool 20% to 15%
    1,800 BPH
    2,445 BPH
    Full Heat 30% to 15%2
    1,400 BPH
    1,825 BPH
    Full Heat 25% to 15%2
    1,825 BPH
    2,475 BPH
    Full Heat 20% to 15%2
    2,950 BPH
    4,000 BPH
    Basic Construction
    3 Modules
    3 Modules
     
    6 Stages
    6 Stages
    Grain Columns
    14" x 20' Long
    14" x 26' Long
    Total Holding Capacity
    1,534 BU
    1,995 BU
    Grain Column Holding Capacity
    1,460 BU
    1,898 BU
    Top Auger (Loading)
    7.5 HP
    10 HP
    Capacity
    3,800 BPH
    3,800 BPH
    Bottom Auger (Unloading)
    7.5 HP
    10 HP
    Meter Roll Drive
    SCR, 3/4 HP
    SCR, 3/4 HP
    Maximum Capacity
    2,800 BPH
    3,640 BPH
    Transport Length (Hitch to Discharge Auger)
    29'2"
    35'2"
    Transport Width
    8'
    8'
    Transport Height3
    13'5" (11'9")
    13'5" (11'9")
    Installed Length
    29'10"
    35'10"
    Installed Width
    8'8"
    8'8"
    Installed Height (Excluding Foundation Supports)
    37'3"
    37'3"
    Fans 1 PH
    N/A
    N/A
    Fans 3 PH
    6@15 HP, 36"
    6@25 HP, 40"
    Heaters (Max BTU)
    6@4.5 Mil. btu/hr
    6@6.75 Mil. btu/hr
    Electric Load (Fan, load Auger, unload. Auger.)4
    Single Phase, 230 V. - Min/Max Amps
    N/A
    N/A
    Three Phase, 230 V. - Min/Max Amps
    275 Amps
    436 Amps
    Three Phase, 380 V. - Min/Max Amps
    188 Amps
    283 Amps
    Three Phase, 460 V. - Min/Max Amps
    137 Amps
    218 Amps
    Three Phase, 575 V. - Min/Max Amps
    110 Amps
    174 Amps

    1Capacities listed are wet bushels, for mature #2 yellow shelled dent corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain's physiological factors (kernal size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.

    2Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin.

    3Shortest possible height in ( ).

    4Minimum: Fan(s) & Dryer Load & Unload motor name plate amperages + 5 for control & SCR load.
    Maximum: Fan(s) & Dryer Load & Unload & largest auxiliary motor name plate amperages + 5 for control & SCR load.