> Home > Commercial > Drying & Conditioning > Portable Dryers
Portable Grain Dryers

GSI offers the most technologically advanced and reliable dryers on the market today. We also have the widest selection of dryer models, suitable for a wide variety of applications. All GSI dryers feature easy-to-use and state-of-the-art controls, heavy-duty galvanized steel construction, and industrial grade electrical components. GSI dryers can help solve even the most complex grain conditioning problems.

Fans and Heaters
GSI’s high efficiency one-piece fan and heater unit provides optimal heated air flow for all dryer applications and utilizes only 1725 rpm low-speed and low-noise fans which are more energy efficient than centrifugal fans in this application. All units feature fiberglass reinforced polypropylene fan blades with a very low starting load, high air flow across a wide static pressure range, precise balance and quiet operation.
Ten different fan configurations are available. An electronic ignition system monitors the burner and a view window provides easy observation. The Optimizer Blue Burn System is standard on all LP models and assures energy efficient operation.

Rear Discharge Auto-Shutdown
A 2’ discharge extension with manual grain sampler is standard equipment. An automatic discharge shutdown operates off of a hinged lid switch at the rear discharge. It is activated when grain overfills the discharge auger and forces the lid to open.

Clean-Out Made Easy
Large plenum clean-out doors make for easy access to the unload auger and metering rolls.
Inside metering and unload auger access panels lift out of the way without tools to better accommodate service and maintenance needs.
Sealing strips reduce air pressure and heat loss into the unload chamber.

8" DURA-EDGE® Auger Flighting
All augers feature the new DURA-EDGE® 8” diameter flighting with 1/4” ribbon. The DURA-EDGE® flighting has an outside edge that is 30% thicker than regular flighting. This contributes to the product’s long life and dependability.

Three-Piece Sidewall Screens
GSI’s three-piece sidewall panels allow the top angle section alone, the top angle and side sections, or all of the exterior screens including the bottom angle section to optionally be stainless steel. This allows for economical protection against rust and corrosion where needed based on the size of the dryer and the type of usage it will experience. All fastening hardware are also stainless steel to eliminate future corrosion.

Access Ladders
GSI ladders feature heavy-duty construction and slip-resistant patterns to give extra grip in wet conditions. Our attention to detail and quality design gives GSI a solid foothold in the grain drying business.
Vision Dryer Controls
The GSI Vision dryer control system features a wide array of settings that offers unparalleled options and control. Boasting a 10.4" TFT color touch screen with easy-to-use controls, the Vision can be remote-mounted, via a simple seven wire harness, up to 1000 feet away from the dryer.
The Vision system features a low voltage safety circuit and a safety disconnect on every dryer. Each safety is monitored individually and its status displayed on-screen. With no moving parts – timers, time delays, thermostats, etc. – the Vision system is less prone to wear-and-tear that leads to costly repairs and downtime. Plenum and grain temperatures can be modified on-screen. You can also change from High/Low to On/Off fire mode which allows plenum operation down to 5 degrees above ambient with a simple software switch. MORE
Specifications
108 |
112 |
114 |
116 |
118 |
120 |
122 |
126 |
|
| Drying Capacity, Shelled Corn1 | ||||||||
| Dry and Cool 25% to 15% Staged Batch | 165 BPH |
220 BPH |
260 BPH |
280 BPH |
320 BPH |
360 BPH |
390 BPH |
455 BPH |
| Dry and Cool 20% to 15% Staged Batch | 220 BPH |
290 BPH |
340 BPH |
370 BPH |
430 BPH |
475 BPH |
520 BPH |
605 BPH |
| Full Heat 30% to 15%2 | 190 BPH |
255 BPH |
300 BPH |
320 BPH |
380 BPH |
415 BPH |
460 BPH |
540 BPH |
| Full Heat 25% to 15%2 | 260 BPH |
345 BPH |
405 BPH |
440 BPH |
505 BPH |
560 BPH |
610 BPH |
715 BPH |
| Full Heat 20% to 15%2 | 420 BPH |
560 BPH |
650 BPH |
710 BPH |
815 BPH |
905 BPH |
990 BPH |
1155 BPH |
| Basic Construction | 1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
|
| Grain Columns | 14" x 8' Long |
14" x 12' Long |
14" x 14' Long |
14" x 16' Long |
14" x 18' Long |
14" x 20' Long |
14" x 22' Long |
14" x 26' Long |
| Total Holding Capacity | 219 BU |
327 BU |
381 BU |
436 BU |
490 BU |
544 BU |
599 BU |
708 BU |
| Grain Column Holding Capacity | 190 BU |
282 BU |
329 BU |
376 BU |
423 BU |
470 BU |
517 BU |
611 BU |
| Top Auger (Loading) | 8' Flight |
8' Flight |
8' Flight |
8' Flight |
8' Flight |
8' Flight |
8' Flight |
8' Flight |
2 HP |
2 HP |
3 HP |
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|
| Capacity | 3800 BPH |
3800 BPH |
3800 BPH |
3800 BPH |
3800 BPH |
3800 BPH |
3800 BPH |
3800 BPH |
| Bottom Auger (Unloading) | 8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
1.5 HP |
1.5 HP |
3 HP |
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
| Maximum Capacity | 1125 BPH |
1680 BPH |
1960 BPH |
2240 BPH |
2520 BPH |
2800 BPH |
3080 BPH |
3640 BPH |
| Transport Length (Hitch to Discharge Auger) | 17'2" |
21'2" |
23'2" |
25'2" |
27'2" |
29'2" |
31'2" |
35'2" |
| Transport Width | 8' |
8' |
8' |
8' |
8' |
8' |
8' |
8' |
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
| Transport Weight (approx.) (Less Transport Kit) | 5,000 lbs. |
6,300 lbs. |
7,000 lbs. |
7,500 lbs. |
8,000 lbs. |
8,700 lbs. |
9,000 lbs. |
11,000 lbs. |
| Installed Length | 15'2" |
19'2" |
21'2" |
23'2" |
25'2" |
27'2" |
29'2" |
33'2" |
| Installed Width | 8' |
8' |
8' |
8' |
8' |
8' |
8' |
8' |
| Installed Height (Excluding Foundation Supports) | 14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
| Fan 1 PH | 10-12 HP, 36" |
10-16 HP, 36" |
10-16 HP, 40" |
10-16 HP, 40" |
N/A |
N/A |
N/A |
N/A |
| Fan 3 PH | 10-12 HP,
36" |
15 HP,
36" |
15 HP,
40" |
15 HP,
40" |
20 HP,
42" |
25 HP,
42" |
30 HP,
42" |
40 HP,
42" |
| Heater (Max BTU) | 3.5 Mil. btu/hr |
4.5 Mil. btu/hr |
5.75 Mil. btu/hr |
5.75 Mil. btu/hr |
6.75 Mil. btu/hr |
7.5 Mil. btu/hr |
8.75 Mil. btu/hr |
10.25 Mil. btu/hr |
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||||||||
| Single Phase, 230 V. - Min/Max Amps | 69/131 |
90/152 |
103/165 |
113/175 |
N/A |
N/A |
N/A |
N/A |
| Three Phase, 208 V. - Min/Max Amps | 55/105 |
68/119 |
75/140 |
88/153 |
102/167 |
134/230 |
148/244 |
182/279 |
| Three Phase, 240 V. - Min/Max Amps | 46/86 |
55/95 |
60/112 |
70/122 |
84/136 |
109/187 |
119/197 |
155/233 |
| Three Phase, 380 V. - Min/Max Amps | 25/51 |
36/61 |
39/70 |
46/77 |
53/84 |
69/119 |
76/126 |
94/144 |
| Three Phase, 480 V. - Min/Max Amps | 26/46 |
30/50 |
33/59 |
38/64 |
45/71 |
57/96 |
62/101 |
80/119 |
| Three Phase, 575 V. - Min/Max Amps | 23/39 |
26/42 |
28/48 |
32/52 |
36/57 |
47/79 |
51/83 |
66/98 |
1108 |
1112 |
1114 |
1116 |
1118 |
1120 |
1122 |
1126 |
|
| Drying Capacity, Shelled Corn1 | ||||||||
| Dry and Cool 25% to 15% Staged Batch | 165 BPH |
220 BPH |
260 BPH |
280 BPH |
320 BPH |
360 BPH |
390 BPH |
455 BPH |
| Dry and Cool 20% to 15% Staged Batch | 220 BPH |
290 BPH |
340 BPH |
370 BPH |
430 BPH |
475 BPH |
520 BPH |
605 BPH |
| Full Heat 30% to 15%2 | 190 BPH |
255 BPH |
300 BPH |
320 BPH |
380 BPH |
415 BPH |
460 BPH |
540 BPH |
| Full Heat 25% to 15%2 | 260 BPH |
345 BPH |
405 BPH |
440 BPH |
505 BPH |
560 BPH |
610 BPH |
715 BPH |
| Full Heat 20% to 15%2 | 420 BPH |
560 BPH |
650 BPH |
710 BPH |
815 BPH |
905 BPH |
990 BPH |
1,155 BPH |
| Basic Construction | 1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
1 Stage |
|
| Grain Columns | 14" x 8' Long |
14" x 12' Long |
14" x 14' Long |
14" x 16' Long |
14" x 18' Long |
14" x 20' Long |
14" x 22' Long |
14" x 26' Long |
| Total Holding Capacity | 219 BU |
327 BU |
381 BU |
436 BU |
490 BU |
544 BU |
599 BU |
708 BU |
| Grain Column Holding Capacity | 190 BU |
282 BU |
329 BU |
376 BU |
423 BU |
470 BU |
517 BU |
611 BU |
| Top Auger (Loading) | 8" Flight |
8" Flight |
8" Flight |
8" Flight |
8" Flight |
8" Flight |
8" Flight |
8" Flight |
2 HP |
2 HP |
3 HP |
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|
| Capacity | 3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
| Bottom Auger (Unloading) | 8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
8" Flight 10" Tube |
1.5 HP |
1.5 HP |
3 HP |
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
| Maximum Capacity | 1,125 BPH |
1,680 BPH |
1,960 BPH |
2,240 BPH |
2,520 BPH |
2,800 BPH |
3,080 BPH |
3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 17'2" |
21'2" |
23'2" |
25'2" |
27'2" |
29'2" |
31'2" |
35'2" |
| Transport Width | 8' |
8' |
8' |
8' |
8' |
8' |
8' |
8' |
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5 (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
| Transport Weight (approx.) (Less Transport Kit) | 5,200 lbs. |
6,300 lbs. |
7,000 lbs. |
7,500 lbs. |
8,000 lbs. |
8,700 lbs. |
9,500 lbs. |
11,000 lbs. |
| Installed Length | 15'2" |
19'2" |
21'2" |
23'2" |
25'2" |
27'2" |
29'2" |
33'2" |
| Installed Width | 8' |
8' |
8' |
8' |
8' |
8' |
8' |
8' |
| Installed Height (Excluding Foundation Supports) | 14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
| Fan 1 PH | 10-16 HP, 36" |
10-16 HP, 36" |
10-16 HP, 40" |
10-16 HP, 40" |
N/A |
N/A |
N/A |
N/A |
| Fan 3 PH | 10-16 HP, 36" |
15 HP, 36" |
15 HP, 40" |
15 HP, 40" |
20 HP, 42" |
25 HP, 42" |
30 HP, 42" |
40 HP, 42" |
| Heater (Max BTU) | 3.5 Mil. btu/hr |
4.5 Mil. btu/hr |
5.75 Mil. btu/hr |
5.75 Mil. btu/hr |
6.75 Mil. btu/hr |
7.5 Mil. btu/hr |
8.75 Mil. btu/hr |
10.25 Mil. btu/hr |
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||||||||
| Single Phase, 230 V. - Min/Max Amps | 101/122 |
101/156 |
109/164 |
124/179 |
N/A |
N/A |
N/A |
N/A |
| Three Phase, 208 V. - Min/Max Amps | 57/95 |
57/95 |
64/115 |
77/127 |
88/138 |
117/193 |
128/204 |
167/244 |
| Three Phase, 230 V. - Min/Max Amps | 53/83 |
53/88 |
60/108 |
71/120 |
81/130 |
107/178 |
117/188 |
157/228 |
| Three Phase, 460 V. - Min/Max Amps | 29/41 |
29/44 |
32/54 |
38/60 |
43/65 |
56/89 |
61/94 |
81/114 |
| Three Phase, 575 V. - Min/Max Amps | 25/36 |
25/36 |
28/45 |
33/50 |
36/54 |
46/73 |
50/77 |
67/94 |
1214 |
1216 |
1218 |
1220 |
1222 |
1226 |
|||
| Drying Capacity, Shelled Corn1 | ||||||||
| Dry and Cool 25% to 15% | 250 BPH |
290 BPH |
315 BPH |
345 BPH |
395 BPH |
450 BPH |
||
| Dry and Cool 20% to 15% | 400 BPH |
465 BPH |
505 BPH |
560 BPH |
640 BPH |
725 BPH |
||
| Full Heat 30% to 15%2 | 335 BPH |
380 BPH |
415 BPH |
436 BPH |
485 BPH |
545 BPH |
||
| Full Heat 25% to 15%2 | 415 BPH |
475 BPH |
520 BPH |
590 BPH |
650 BPH |
730 BPH |
||
| Full Heat 20% to 15%2 | 680 BPH |
765 BPH |
840 BPH |
950 BPH |
1,055 BPH |
1,180 BPH |
||
| Basic Construction | 1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
||
2 Stages |
2 Stages |
2 Stages |
2 Stages |
2 Stages |
2 Stages |
|||
| Grain Columns | 14" x 14' Long |
14" x 16' Long |
14" x 18' Long |
14" x 20' Long |
14" x 22' Long |
14" x 26' Long |
||
| Total Holding Capacity | 381 BU |
436 BU |
490 BU |
544 BU |
599 BU |
708 BU |
||
| Grain Column Holding Capacity | 329 BU |
376 BU |
423 BU |
470 BU |
517 BU |
611 BU |
||
| Top Auger (Loading) | 8", 5 HP |
8", 5 HP |
8", 5 HP |
8", 7.5 HP |
8", 7.5 HP |
8", 10 HP |
||
| Capacity | 3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
||
| Bottom Auger (Unloading) | 8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
||
5 HP |
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|||
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
||
| Maximum Capacity | 1,960 BPH |
2,240 BPH |
2,520 BPH |
2,800 BPH |
3,080 BPH |
3,640 BPH |
||
| Transport Length (Hitch to Discharge Auger) | 23'2" |
25'2" |
27'2" |
29'2" |
31'2" |
35'2" |
||
| Transport Width | 8' |
8' |
8' |
8' |
8' |
8' |
||
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5"(11'9") |
13'5" (11'9") |
||
| Transport Weight (approx.) (Less Transport Kit) | 7,600 lbs. |
8,200 lbs. |
9,000 lbs. |
9,800 lbs. |
10,500 lbs. |
12,000 lbs. |
||
| Installed Length | 21'2" |
23'2" |
25'2" |
27'2" |
29'2" |
33'2" |
||
| Installed Width | 8' |
8' |
8' |
8' |
8' |
8' |
||
| Installed Height (Excluding Foundation Supports) | 14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
||
| Fans 1 PH | 1@10-12 HP, 36" |
1@15 HP, 36" |
1@15 HP, 36" |
1@15 HP, 40" |
N/A |
N/A |
||
1@10-12 HP, 26" |
1@10-12 HP,
26" |
1@10-12 HP,
26" |
1@10-12 HP,
28" |
N/A |
N/A |
|||
| Fans 3 PH | 1@10-12 HP, 36" |
1@15 HP, 36" |
1@15 HP, 36" |
1@15 HP, 40" |
1@20 HP,
42" |
1@25 HP,
42" |
||
1@10-12 HP, 26" |
1@10-12 HP,
26" |
1@10-12 HP,
26" |
1@10-12 HP,
28" |
1@10-12 HP,
28" |
1@10-12 HP,
28" |
|||
| Heaters (Max BTU) | 1@3.5 Mil. btu/hr |
1@4.5 Mil. btu/hr |
1@4.5 Mil. btu/hr |
1@5.5 Mil. btu/hr |
1@6.75 Mil. btu/hr |
1@7.5 Mil. btu/hr |
||
1@2.7 Mil. btu/hr |
1@2.7 Mil. btu/hr |
1@2.7 Mil. btu/hr |
1@3.0 Mil. btu/hr |
1@3.0 Mil. btu/hr |
1@3.0 Mil. btu/hr |
|||
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||||||||
| Single Phase, 230 V. - Min/Max Amps | 157/212 |
177/232 |
177/232 |
191/246 |
N/A |
N/A |
||
| Three Phase, 208 V. - Min/Max Amps | 112/162 |
112/162 |
112/162 |
125/202 |
136/213 |
164/240 |
||
| Three Phase, 230 V. - Min/Max Amps | 99/148 |
104/153 |
104/153 |
116/187 |
126/197 |
154/225 |
||
| Three Phase, 460 V. - Min/Max Amps | 52/74 |
55/76 |
55/76 |
61/93 |
66/98 |
80/112 |
||
| Three Phase, 575 V. - Min/Max Amps | 48/66 |
49/66 |
49/66 |
54/81 |
57/84 |
68/95 |
||
1214S |
1218S |
1220S & 1220H* |
1222S & 1222H* |
1226S & 1226H* |
||||
| Drying Capacity, Shelled Corn1 | ||||||||
| Dry and Cool 25% to 15% Staged Batch | 260 BPH |
345 BPH |
395 BPH |
430 BPH |
530 BPH |
|||
| Dry and Cool 20% to 15% Staged Batch | 360 BPH |
450 BPH |
520 BPH |
565 BPH |
700 BPH |
|||
| Dry and Cool 25% to 15% | 185 BPH |
240 BPH |
280 BPH |
300 BPH |
375 BPH |
|||
| Dry and Cool 20% to 15% | 300 BPH |
385 BPH |
445 BPH |
485 BPH |
600 BPH |
|||
| Full Heat 30% to 15%2 | 305 BPH |
395 BPH |
455 BPH |
495 BPH |
620 BPH |
|||
| Full Heat 25% to 15%2 | 410 BPH |
535 BPH |
615 BPH |
670 BPH |
820 BPH |
|||
| Full Heat 20% to 15%2 | 675 BPH |
860 BPH |
990 BPH |
1,080 BPH |
1,330 BPH |
|||
| Basic Construction | 1 Module |
1 Module |
1 Module |
1 Module |
1 Module |
|||
2 Stages |
2 Stages |
2 Stages |
2 Stages |
2 Stages |
||||
| Grain Columns | 14" x 14' Long |
14" x 18' Long |
14" x 20' Long |
14" x 22' Long |
14" x 26' Long |
|||
| Total Holding Capacity | 381 BU |
490 BU |
544 BU |
599 BU |
708 BU |
|||
| Grain Column Holding Capacity | 329 BU |
423 BU |
470 BU |
517 BU |
611 BU |
|||
| Top Auger (Loading) | 5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|||
| Capacity | 3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
|||
| Bottom Auger (Unloading) | 8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
|||
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
||||
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
|||
| Maximum Capacity | 1,960 BPH |
2,520 BPH |
2,800 BPH |
3,080 BPH |
3,640 BPH |
|||
| Transport Length (Hitch to Discharge Auger) | 23'2" |
27'2" |
29'2" |
31'2" |
35'2" |
|||
| Transport Width | 8' |
8' |
8' |
8' |
8' |
|||
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5"(11'9") |
13'5" (11'9") |
|||
| Transport Weight (approx.) (Less Transport Kit) | 9,500 lbs. |
11,500 lbs. |
14,500 lbs. |
15,500 lbs. |
18,500 lbs. |
|||
| Installed Length | 21'2" |
25'2" |
27'2" |
30'2" |
33'2" |
|||
| Installed Width | 8'8" |
8'8" |
8'8" |
8'8" |
8'8" |
|||
| Installed Height (Excluding Foundation Supports) | 14'6" |
14'6" |
14'6" |
14'6" |
14'6" |
|||
| Fans 1 PH | 2@10-12 HP, 28" |
2@10-12 HP, 36" |
2@15 HP, 36" |
2@15 HP, 36" |
N/A |
|||
| Fans 3 PH | 2@10-12 HP, 28" |
2@10-12 HP, 36" |
2@15 HP, 36" |
2@15 HP, 36" |
2@25 HP, 40" |
|||
| Heaters (Max BTU) | 2@3.0 Mil. btu/hr |
2@3.5 Mil. btu/hr |
2@4.5 Mil. btu/hr |
2@4.5 Mil. btu/hr |
2@6.75 Mil. btu/hr |
|||
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||||||||
| Single Phase, 230 V. - Min/Max Amps | 157/212 |
157/212 |
211/266 |
211/266 |
N/A |
|||
| Three Phase, 208 V. - Min/Max Amps | 106/156 |
106/144 |
131/208 |
131/208 |
196/273 |
|||
| Three Phase, 230 V. - Min/Max Amps | 99/148 |
99/134 |
121/192 |
121/192 |
183/254 |
|||
| Three Phase, 460 V. - Min/Max Amps | 52/74 |
52/68 |
63/96 |
63/96 |
94/127 |
|||
| Three Phase, 575 V. - Min/Max Amps | 48/66 |
48/66 |
54/81 |
54/81 |
77/104 |
|||
*Note: S-Series dryers are upgradable with additional modules while the H-Series is not.
2314 |
2318 |
2320 |
2322 |
2326 |
||||
| Drying Capacity, Shelled Corn1 | ||||||||
| Dry and Cool 25% to 15% | 615 BPH |
770 BPH |
850 BPH |
930 BPH |
1,130 BPH |
|||
| Dry and Cool 20% to 15% | 995 BPH |
1,235 BPH |
1,375 BPH |
1,500 BPH |
1,835 BPH |
|||
| Full Heat 30% to 15%2 | 670 BPH |
830 BPH |
925 BPH |
1,010 BPH |
1,200 BPH |
|||
| Full Heat 25% to 15%2 | 900 BPH |
1,120 BPH |
1,245 BPH |
1,355 BPH |
1,670 BPH |
|||
| Full Heat 20% to 15%2 | 1,455 BPH |
1,805 BPH |
2,010 BPH |
2,195 BPH |
2,700 BPH |
|||
| Basic Construction | 2 Modules |
2 Modules |
2 Modules |
2 Modules |
2 Modules |
|||
4 Stages |
4 Stages |
4 Stages |
4 Stages |
4 Stages |
||||
| Grain Columns | 14" x 14' Long |
14" x 18' Long |
14" x 20' Long |
14" x 22' Long |
14" x 26' Long |
|||
| Total Holding Capacity | 731 BU |
940 BU |
1,044 BU |
1,149 BU |
1,304 BU |
|||
| Grain Column Holding Capacity | 679 BU |
873 BU |
970 BU |
1,067 BU |
1,261 BU |
|||
| Top Auger (Loading) | 5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|||
| Capacity | 3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
|||
| Bottom Auger (Unloading) | 8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
|||
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
||||
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
|||
| Maximum Capacity | 1,960 BPH |
2,520 BPH |
2,800 BPH |
3,080 BPH |
3,640 BPH |
|||
| Transport Length (Hitch to Discharge Auger) | 23'2" |
27'2" |
29'2" |
31'2" |
35'2" |
|||
| Transport Width | 8' |
8' |
8' |
8' |
8' |
|||
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5"(11'9") |
13'5" (11'9") |
|||
| Transport Weight (approx.) (Less Transport Kit) | 16,000 lbs. |
19,000 lbs. |
21,000 lbs. |
22,500 lbs. |
25,000 lbs. |
|||
| Installed Length | 23'10" |
27'10" |
29'10" |
31'10" |
35'10" |
|||
| Installed Width | 8'8" |
8'8" |
8'8" |
8'8" |
8'8" |
|||
| Installed Height (Excluding Foundation Supports) | 25'11" |
25'11" |
25'11" |
25'11" |
25'11" |
|||
| Fans 1 PH | 1@15 HP, 40" |
N/A |
N/A |
N/A |
N/A |
|||
2@10-12 HP, 28" |
N/A |
N/A |
N/A |
N/A |
||||
| Fans 3 PH | 1@15 HP, 40" |
1@20 HP, 42" |
1@25 HP, 42" |
1@30 HP, 42" |
1@40?HP, 42" |
|||
2@10-12 HP, 28" |
2@10-12 HP, 36" |
2@15 HP, 36" |
2@15 HP, 36" |
2@25 HP, 40" |
||||
| Heaters (Max BTU) | 1@5.5 Mil. btu/hr |
1@6.75 Mil. btu/hr |
1@7.5 Mil. btu/hr |
1@8.75 Mil. btu/hr |
1@10.75 Mil. btu/hr |
|||
2@3.0 Mil. btu/hr |
2@3.5 Mil. btu/hr |
2@4.5 Mil. btu/hr |
2@4.5 Mil. btu/hr |
2@6.75 Mil. btu/hr |
||||
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||||||||
| Single Phase, 230 V. - Min/Max Amps | 230/285 |
N/A |
N/A |
N/A |
N/A |
|||
| Three Phase, 208 V. - Min/Max Amps | 147/197 |
158/208 |
199/275 |
199/275 |
302/379 |
|||
| Three Phase, 230 V. - Min/Max Amps | 137/186 |
135/184 |
183/254 |
183/254 |
281/352 |
|||
| Three Phase, 460 V. - Min/Max Amps | 71/93 |
70/92 |
94/127 |
99/132 |
143/176 |
|||
| Three Phase, 575 V. - Min/Max Amps | 65/82 |
68/86 |
78/105 |
82/109 |
115/142 |
|||
2420 |
2426 |
|
| Drying Capacity, Shelled Corn1 | ||
| Dry and Cool 25% to 15% | 850 BPH |
1,130 BPH |
| Dry and Cool 20% to 15% | 1,375 BPH |
1,835 BPH |
| Full Heat 30% to 15%2 | 925 BPH |
1,200 BPH |
| Full Heat 25% to 15%2 | 1,245 BPH |
1,670 BPH |
| Full Heat 20% to 15%2 | 2,010 BPH |
2,700 BPH |
| Basic Construction | 2 Modules |
2 Modules |
4 Stages |
4 Stages |
|
| Grain Columns | 14" x 22' Long |
14" x 26' Long |
| Total Holding Capacity | 1,044 BU |
1,340 BU |
| Grain Column Holding Capacity | 970 BU |
1,261 BU |
| Top Auger (Loading) | 7.5 HP |
10 HP |
| Capacity | 3,800 BPH |
3,800 BPH |
| Bottom Auger (Unloading) | 7.5 HP |
10 HP |
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
| Maximum Capacity | 2,800 BPH |
3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 29'2" |
35'2" |
| Transport Width | 8' |
8' |
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
| Installed Length | 29'10" |
35-10 |
| Installed Width | 8'8" |
8'8" |
| Installed Height (Excluding Foundation Supports) | 25'11" |
25'11" |
| Fans 1 PH | N/A |
N/A |
| Fans 3 PH | 4@15 HP, 36" |
4@25 HP, 40" |
| Heaters (Max BTU) | 4@4.5 Mil. btu/hr |
4@6.75 Mil. btu/hr |
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||
| Single Phase, 230 V. - Min/Max Amps | N/A |
N/A |
| Three Phase, 230 V. - Min/Max Amps | 196 Amps |
308 Amps |
| Three Phase, 380 V. - Min/Max Amps | 134 Amps |
199 Amps |
| Three Phase, 460 V. - Min/Max Amps | 98 Amps |
154 Amps |
| Three Phase, 575 V. - Min/Max Amps | 80 Amps |
124 Amps |
3414 |
3418 |
3420 |
3422 |
3426 |
||||
| Drying Capacity, Shelled Corn1 | ||||||||
| Dry and Cool 25% to 15% | 840 BPH |
1,035 BPH |
1,120 BPH |
1,250 BPH |
1,520 BPH |
|||
| Dry and Cool 20% to 15% | 1,340 BPH |
1,665 BPH |
1,800 BPH |
2,015 BPH |
2,445 BPH |
|||
| Full Heat 30% to 15%2 | 1,000 BPH |
1,250 BPH |
1,400 BPH |
1,515 BPH |
1,825 BPH |
|||
| Full Heat 25% to 15%2 | 1,355 BPH |
1,680 BPH |
1,825 BPH |
2,040 BPH |
2,475 BPH |
|||
| Full Heat 20% to 15%2 | 2,190 BPH |
2,720 BPH |
2,950 BPH* |
3,300 BPH* |
4,000 BPH* |
|||
| Basic Construction | 3 Modules |
3 Modules |
3 Modules |
3 Modules |
3 Modules |
|||
6 Stages |
6 Stages |
6 Stages |
6 Stages |
6 Stages |
||||
| Grain Columns | 14" x 14' Long |
14" x 18' Long |
14" x 20' Long |
14" x 22' Long |
14" x 26' Long |
|||
| Total Holding Capacity | 1,074 BU |
1,381 BU |
1,534 BU |
1,688 BU |
1,995 BU |
|||
| Grain Column Holding Capacity | 1,022 BU |
1,314 BU |
1,460 BU |
1,606 BU |
1,898 BU |
|||
| Top Auger (Loading) | 5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
|||
| Capacity | 3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
3,800 BPH |
|||
| Bottom Auger (Unloading) | 8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
8" Flight/10" Tube |
|||
5 HP |
5 HP |
7.5 HP |
7.5 HP |
10 HP |
||||
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
SCR, 3/4 HP |
|||
| Maximum Capacity | 1,960 BPH |
2,520 BPH |
2,800 BPH |
3,080 BPH |
3,640 BPH |
|||
| Transport Length (Hitch to Discharge Auger) | 23'2" |
27'2" |
29'2" |
31'2" |
35'2" |
|||
| Transport Width | 8 |
8 |
8 |
8 |
8 |
|||
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
13'5" (11'9") |
|||
| Transport Weight (approx.) (Less Transport Kit) | 23,000 lbs. |
26,500 lbs. |
29,500 lbs. |
30,500 lbs. |
35,000 lbs. |
|||
| Installed Length | 23'10" |
27'10" |
29'10" |
31'10" |
35'10" |
|||
| Installed Width | 8-8 |
8-8 |
8-8 |
8-8 |
8-8 |
|||
| Installed Height (Excluding Foundation Supports) | 37'3" |
37'3" |
37'3" |
37'3" |
37'3" |
|||
| Fans 1 PH | 2@15 HP, 40" |
N/A |
N/A |
N/A |
N/A |
|||
2@10-12 HP, 28" |
N/A |
N/A |
N/A |
N/A |
||||
| Fans 3 PH | 2@15 HP, 40" |
2@20 HP, 42" |
2@25 HP, 42" |
2@30 HP, 42" |
2@40 HP, 42" |
|||
2@10-12 HP, 28" |
2@10-12 HP, 36" |
2@15 HP, 36" |
2@15 HP, 36" |
2@25 HP, 40" |
||||
| Heaters (Max BTU) | 2@5.5 Mil. btu/hr |
2@6.75 Mil. btu/hr |
2@7.5 Mil. btu/hr |
2@8.75 Mil. btu/hr |
2@10.25 Mil. btu/hr |
|||
2@3.0 Mil. btu/hr |
2@3.5 Mil. btu/hr |
2@4.5 Mil. btu/hr |
2@4.5 Mil. btu/hr |
2@6.75 Mil. btu/hr |
||||
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||||||||
| Single Phase, 230 V. - Min/Max Amps | 303/358 |
N/A |
N/A |
N/A |
N/A |
|||
| Three Phase, 208 V. - Min/Max Amps | 188/238 |
210/260 |
266/343 |
266/343 |
300/377 |
|||
| Three Phase, 230 V. - Min/Max Amps | 175/224 |
183/232 |
245/316 |
245/316 |
279/350 |
|||
| Three Phase, 460 V. - Min/Max Amps | 90/112 |
94/116 |
125/158 |
135/168 |
192/225 |
|||
| Three Phase, 575 V. - Min/Max Amps | 81/98 |
88/106 |
103/130 |
111/138 |
154/181 |
|||
* Limited by Meter Roll maximum capacity.
3620 |
3626 |
|
| Drying Capacity, Shelled Corn1 | ||
| Dry and Cool 25% to 15% | 1,120 BPH |
1,520 BPH |
| Dry and Cool 20% to 15% | 1,800 BPH |
2,445 BPH |
| Full Heat 30% to 15%2 | 1,400 BPH |
1,825 BPH |
| Full Heat 25% to 15%2 | 1,825 BPH |
2,475 BPH |
| Full Heat 20% to 15%2 | 2,950 BPH |
4,000 BPH |
| Basic Construction | 3 Modules |
3 Modules |
6 Stages |
6 Stages |
|
| Grain Columns | 14" x 20' Long |
14" x 26' Long |
| Total Holding Capacity | 1,534 BU |
1,995 BU |
| Grain Column Holding Capacity | 1,460 BU |
1,898 BU |
| Top Auger (Loading) | 7.5 HP |
10 HP |
| Capacity | 3,800 BPH |
3,800 BPH |
| Bottom Auger (Unloading) | 7.5 HP |
10 HP |
| Meter Roll Drive | SCR, 3/4 HP |
SCR, 3/4 HP |
| Maximum Capacity | 2,800 BPH |
3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 29'2" |
35'2" |
| Transport Width | 8' |
8' |
| Transport Height3 | 13'5" (11'9") |
13'5" (11'9") |
| Installed Length | 29'10" |
35'10" |
| Installed Width | 8'8" |
8'8" |
| Installed Height (Excluding Foundation Supports) | 37'3" |
37'3" |
| Fans 1 PH | N/A |
N/A |
| Fans 3 PH | 6@15 HP, 36" |
6@25 HP, 40" |
| Heaters (Max BTU) | 6@4.5 Mil. btu/hr |
6@6.75 Mil. btu/hr |
| Electric Load (Fan, load Auger, unload. Auger.)4 | ||
| Single Phase, 230 V. - Min/Max Amps | N/A |
N/A |
| Three Phase, 230 V. - Min/Max Amps | 275 Amps |
436 Amps |
| Three Phase, 380 V. - Min/Max Amps | 188 Amps |
283 Amps |
| Three Phase, 460 V. - Min/Max Amps | 137 Amps |
218 Amps |
| Three Phase, 575 V. - Min/Max Amps | 110 Amps |
174 Amps |
1Capacities listed are wet bushels, shelled corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain's physiological factors (kernal size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.
2Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin. 3Shortest possible height in ( ). 4Minimum: Fan(s) & Dryer Load & Unload motor name plate amperages + 5 for control & SCR load.
Maximum: Fan(s) & Dryer Load & Unload & largest auxiliary motor name plate amperages + 5 for control & SCR load.