Network
Series Dryer Specifications
GSI offers several models of the Network Series Dryer to meet your
specific drying capacity requirements. The easy to operate network
controls, which can be mounted on site or remotely, offer a great
deal of flexibility and convenience to installations large and small. |
 |
 |
 |
 |
 |
 |
| |
|
|
|
|
|
| |
1100
|
1200 |
1200S |
2300 |
3400 |
 |
 |
 |
 |
|
 |
 |
| |
Drying
Capacity Shelled Corn *1
------ 1200S Models (1214S
- 1226S) |
| |
Model
Numbers |
1214S
|
1218S
|
1220S
|
1222S
|
1226S
|
| |
Dry
and Cool 25% to 15%
(Staged Batch)
|
260
BPH
|
345
BPH
|
395
BPH
|
430
BPH
|
530
BPH
|
| |
Dry
and Cool 20% to 15%
(Staged Batch) |
360
BPH
|
450
BPH
|
520
BPH
|
565
BPH
|
700
BPH
|
| |
Dry
and Cool 25% to 15% |
200
BPH
|
240
BPH
|
280
BPH
|
300
BPH
|
375
BPH
|
| |
Dry
and Cool 20% to 15% |
325
BPH
|
385
BPH
|
445
BPH
|
485
BPH
|
600
BPH
|
| |
Full
Heat 30% to 15% *2 |
305
BPH
|
395
BPH
|
455
BPH
|
495
BPH
|
620
BPH
|
| |
Full
Heat 25% to 15% *2 |
450
BPH
|
535
BPH
|
615
BPH
|
670
BPH
|
820
BPH
|
| |
Full
Heat 20% to 15% *2 |
725
BPH
|
860
BPH
|
990
BPH
|
1080
BPH
|
1330
BPH
|
| |
|
|
|
|
|
|
| |
Basic
Construction |
1
Module
|
1
Module
|
1
Module
|
1
Module
|
1
Module
|
| |
|
2
Stages
|
2
Stages
|
2
Stages
|
2
Stages
|
2
Stages
|
| |
|
|
|
|
|
|
| |
Grain
Columns |
14" x 14'
Long
|
14" x 18'
Long
|
14" x 20'
Long
|
14" x 22'
Long
|
14" x 26'
Long
|
| |
Total
Holding Capacity |
381
Bu
|
490
Bu
|
544
Bu
|
599
Bu
|
708
Bu
|
| |
Grain
Column Holding Capacity |
329
Bu
|
423
Bu
|
470
Bu
|
517
Bu
|
611
Bu
|
| |
Top
Auger (Loading) |
5
HP
|
5
HP
|
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Capacity
|
3800
BPH
|
3800
BPH
|
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
5 HP
|
5
HP
|
7.5
HP
|
7.5 HP
|
10 HP
|
| |
Meter
Roll Drive |
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
| |
Maximum
Capacity |
1960
BPH
|
2520
BPH
|
2800
BPH
|
3080
BPH
|
3640
BPH
|
| |
|
|
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
23'-2"
|
27'-2"
|
29'-2"
|
31'-2"
|
35'-2"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
|
|
|
|
|
|
| |
Installed
Length |
21'-2"
|
25'-2"
|
27'-2"
|
30'-2"
|
33'-2"
|
| |
Installed
Width |
8'-
8"
|
8'-
8"
|
8'-
8"
|
8'-
8"
|
8'-
8"
|
| |
Installed
Height
(Excluding Foundation Supports) |
14'-6"
|
14'-6"
|
14'-6"
|
14'-6"
|
14'-6"
|
| |
|
|
|
|
|
|
| |
Fans:
1 PH |
2@10-12
HP, 28"
|
2@10-12
HP, 36"
|
2@15
HP, 36"
|
2@15
HP, 36"
|
N/A
|
| |
Fans:
3 PH |
2@10-12
HP, 28"
|
2@10-12
HP, 36"
|
2@15
HP, 36"
|
2@15
HP, 36"
|
2@25
HP, 40"
|
| |
Heaters
(Max. BTU) |
2@3.0
Mil.btu/hr.
|
2@3.5
Mil.btu/hr.
|
2@4.5
Mil.btu/hr.
|
2@4.5
Mil.btu/hr.
|
2@6.75
Mil.btu/hr.
|
| |
|
|
|
|
|
|
| |
Electric
Load
(Fan, Top Auger, Bottom Auger)*4 |
|
|
|
|
|
| |
Single
Phase, 230 V. |
142
Amps
|
142
Amps
|
186
Amps
|
186
Amps
|
N/A
|
| |
Three
Phase, 230 V. |
93
Amps
|
93
Amps
|
118
Amps
|
118
Amps
|
180
Amps
|
| |
Three
Phase, 380 V. |
50
Amps
|
50
Amps
|
80
Amps
|
80
Amps
|
115
Amps
|
| |
Three
Phase, 460 V. |
47
Amps
|
47
Amps
|
60
Amps
|
60
Amps
|
90
Amps
|
| |
Three
Phase, 575 V. |
40
Amps
|
33
Amps
|
48
Amps
|
48
Amps
|
72
Amps
|
| |
|
|
|
|
|
|
| |
*1
- Capacities are wet bushels at input moisture content.
*2 - Grain discharged hot from the dryer will result in a final moisture
content of 15% after cooling in the bin.
*3 - Shortest possible height in ( ).
*4 - Maximum running load less auxiliary auger motors. |
|