GSI International GSI
Home | About GSI | Sales & Support
Competitor Dryers--|--Network Dryers --|--Tower Dryers --|--Process Dryers --|--TopDry--|--Fans and Heaters
--> Home > Drying Systems > Network Dryers > Network 2300 Dryer Specifications
Network Series Dryer Specifications
GSI offers several models of the Network Series Dryer to meet your specific drying capacity requirements. The easy to operate network controls, which can be mounted on site or remotely, offer a great deal of flexibility and convenience to installations large and small.

1100 Models 1200 Models 1200S Models 3400 Models
           
  1100 1200 1200S 2300 3400
  Drying Capacity Shelled Corn *1 ------ 2300 Models (2314 - 2326)
  Model Numbers
2314
2318
2320
2322
2326
  Dry and Cool 25% to 15%
615 BPH
770 BPH
850 BPH
930 BPH
1130 BPH
  Dry and Cool 20% to 15%
995 BPH
1235 BPH
1375 BPH
1500 BPH
1835 BPH
  Full Heat 30% to 15% *2
670 BPH
830 BPH
925 BPH
1010 BPH
1200 BPH
  Full Heat 25% to 15% *2
900 BPH
1120 BPH
1245 BPH
1355 BPH
1670 BPH
  Full Heat 20% to 15% *2
1455 BPH
1805 BPH
2010 BPH
2195 BPH
2700 BPH
             
  Basic Construction
2 Module
2 Module
2 Module
2 Module
2 Module
   
4 Stages
4 Stages
4 Stages
4 Stages
4 Stages
             
  Grain Columns
14" x 14'
Long
14" x 18'
Long
14" x 20'
Long
14" x 22'
Long
14" x 26'
Long
  Total Holding Capacity
731 Bu
940 Bu
1044 Bu
1149 Bu
1304 Bu
  Grain Column Holding Capacity
679 Bu
873 Bu
970 Bu
1067 Bu
1261 Bu
  Top Auger (Loading)
5 HP
5 HP
7.5 HP
7.5 HP
10 HP
  Capacity
3800 BPH
3800 BPH
3800 BPH
3800 BPH
3800 BPH
  Bottom Auger (Unloading)
5 HP
5 HP
7.5 HP
7.5 HP
10 HP
  Meter Roll Drive
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
  Maximum Capacity
1960 BPH
2520 BPH
2800 BPH
3080 BPH
3640 BPH
             
  Transport Length
(Hitch to Discharge Auger)
23'-2"
27'-2"
29'-2"
31'-2"
35'-2"
  Transport Width
8'
8'
8'
8'
8'
  Transport Height *3
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
             
  Installed Length
23'-10"
27'-10"
29'-10"
31'-10"
35'-10"
  Installed Width
8'- 8"
8'- 8"
8'- 8"
8'- 8"
8'- 8"
  Installed Height
(Excluding Foundation Supports)
25'-11"
25'-11"
25'-11"
25'-11"
25'-11"
             
  Fans: 1 PH
2@15 HP, 40"
N/A
N/A
N/A
N/A
   
2@10-12 HP, 28"
N/A
N/A
N/A
N/A
  Fans: 3 PH
1@15 HP, 42"
1@20 HP, 42"
1@25 HP, 42"
1@30 HP, 42"
1@40 HP, 42"
   
2@10-12 HP, 28"
2@10-12 HP, 36"
2@15 HP, 36"
2@15 HP, 36"
2@25 HP, 40"
  Heaters (Max. BTU)
1@5.5 Mil.btu/hr.
1@6.75 Mil.btu/hr.
1@7.5 Mil.btu/hr.
1@8.75 Mil.btu/hr.
1@10.75 Mil.btu/hr.
   
2@3.0 Mil.btu/hr.
2@3.5 Mil.btu/hr.
2@4.5 Mil.btu/hr.
2@4.5 Mil.btu/hr.
2@6.75 Mil.btu/hr.
             
  Electric Load
(Fan, Top Auger, Bottom Auger)*4
         
  Single Phase, 230 V.
204 Amps
N/A
N/A
N/A
N/A
  Three Phase, 230 V.
132 Amps
146 Amps
182 Amps
192 Amps
278 Amps
  Three Phase, 380 V.
77 Amps
82 Amps
122 Amps
129 Amps
172 Amps
  Three Phase, 460 V.
66 Amps
73 Amps
91 Amps
96 Amps
139 Amps
  Three Phase, 575 V.
56 Amps
54 Amps
74 Amps
78 Amps
112 Amps
             
  *1 - Capacities are wet bushels at input moisture content.
*2 - Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin.
*3 - Shortest possible height in ( ).
*4 - Maximum running load less auxiliary auger motors.

 


Network Dryer Controls

Competitor Dryers | Network Dryers
Tower Dryers | Process Dryers | TopDry | Fans and Heaters

Grain Storage | Grain Drying and Conditioning | Material Handling
Home | About GSI | Sales & Support | FAQ's