Network
Series Dryer Specifications
GSI offers several models of the Network Series Dryer to meet your
specific drying capacity requirements. The easy to operate network
controls, which can be mounted on site or remotely, offer a great
deal of flexibility and convenience to installations large and small. |
 |
 |
 |
 |
 |
 |
 |
| |
|
|
|
|
|
|
| |
1100
|
1200 |
1200S |
2300 |
3300 |
3400 |
 |
 |
 |
 |
 |
| |
Drying
Capacity Shelled Corn *1
------ 3300 Models (3312
- 3326) |
| |
Model
Numbers |
3312
|
3314
|
3318
|
| |
Dry
and Cool 25% to 15% |
640
BPH
|
840
BPH
|
1035
BPH
|
| |
Dry
and Cool 20% to 15% |
1035
BPH
|
1340
BPH
|
1665
BPH
|
| |
Full
Heat 30% to 15% *2 |
755
BPH
|
980
BPH
|
1215
BPH
|
| |
Full
Heat 25% to 15% *2 |
1045
BPH
|
1355
BPH
|
1680
BPH
|
| |
Full
Heat 20% to 15% *2 |
1690
BPH
|
2190
BPH
|
2720
BPH
|
| |
|
|
|
|
| |
Basic
Construction |
3
Modules
|
3
Modules
|
3
Modules
|
| |
|
3
Stages
|
3
Stages
|
3
Stages
|
| |
|
|
|
|
| |
Grain
Columns |
14" x 12' Long
|
14" x 14' Long
|
14" x 18' Long
|
| |
Total
Holding Capacity |
921
Bu
|
1074
Bu
|
1381
Bu
|
| |
Grain
Column Holding Capacity |
876
Bu
|
1022
Bu
|
1314
Bu
|
| |
Top
Auger (Loading) |
3
HP
|
5
HP
|
5
HP
|
| |
Capacity
|
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
3
HP
|
5
HP
|
5
HP
|
| |
Meter
Roll Drive |
SCR,
1/3 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
| |
Maximum
Capacity |
1680
BPH
|
1960
BPH
|
2520
BPH
|
| |
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
21'-2 "
|
23'-2"
|
27'-2"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
Installed
Length |
21'-6"
|
23'-10"
|
27'-10"
|
| |
Installed
Width |
8'-8"
|
8'-8"
|
8'-8"
|
| |
Installed
Height
(Excluding Foundation Supports) |
37'-3"
|
37'-3"
|
37'-3"
|
| |
|
|
|
|
| |
Fans:
1 PH |
3@15
HP, 36"
|
3@15
HP, 40"
|
N/A
|
| |
Fans:
3 PH |
3@15
HP, 36"
|
3@15
HP, 42"
|
3@20
HP, 42"
|
| |
Heaters
(Max. BTU) |
3@4.5
Mil.btu/hr
|
3@5.5
Mil.btu/hr
|
3@6.75
Mil.btu/hr
|
| |
|
|
|
|
| |
Electric
Load
(Fan, Top Auger, Bottom Auger)*4 |
|
|
|
| |
Single
Phase, 230 V. |
222
Amps
|
232
Amps
|
N/A
|
| |
Three
Phase, 230 V. |
134
Amps
|
143
Amps
|
186
Amps
|
| |
Three
Phase, 380 V. |
90
Amps
|
98
Amps
|
113
Amps
|
| |
Three
Phase, 460 V. |
67
Amps
|
72
Amps
|
93
Amps
|
| |
Three
Phase, 575 V. |
55
Amps
|
59
Amps
|
73
Amps
|
 |
 |
 |
 |
 |
| |
Drying
Capacity Shelled Corn *1
------ 3300 Models (3314
- 3326) |
| |
Model
Numbers |
3320
|
3322
|
3326
|
| |
Dry
and Cool 25% to 15% |
1120
BPH
|
1250
BPH
|
1520
BPH
|
| |
Dry
and Cool 20% to 15% |
1800
BPH
|
2015
BPH
|
2445
BPH
|
| |
Full
Heat 30% to 15% *2 |
1320
BPH
|
1475
BPH
|
1785
BPH
|
| |
Full
Heat 25% to 15% *2 |
1825
BPH
|
2040
BPH
|
2475
BPH
|
| |
Full
Heat 20% to 15% *2 |
2950
BPH
|
3300
BPH
|
4000
BPH
|
| |
|
|
|
|
| |
Basic
Construction |
3
Modules
|
3
Modules
|
3
Modules
|
| |
|
3
Stages
|
3
Stages
|
3
Stages
|
| |
|
|
|
|
| |
Grain
Columns |
14" x 20' Long
|
14" x 22' Long
|
14" x 26' Long
|
| |
Total
Holding Capacity |
1534
Bu
|
1688
Bu
|
1995
Bu
|
| |
Grain
Column Holding Capacity |
1460
Bu
|
1606
Bu
|
1898
Bu
|
| |
Top
Auger (Loading) |
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Capacity
|
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Meter
Roll Drive |
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
| |
Maximum
Capacity |
2800
BPH
|
3080
BPH
|
3640
BPH
|
| |
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
29'-2"
|
31'-2"
|
35'-2"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
Installed
Length |
29'-10"
|
31'-10"
|
35'-10"
|
| |
Installed
Width |
8'-8"
|
8'-8"
|
8'-8"
|
| |
Installed
Height
(Excluding Foundation Supports) |
37'-3"
|
37'-3"
|
37'-3"
|
| |
|
|
|
|
| |
Fans:
1 PH |
N/A
|
N/A
|
N/A
|
| |
Fans:
3 PH |
3@25
HP, 42"
|
3@30
HP, 42"
|
3@40
HP, 42"
|
| |
Heaters
(Max. BTU) |
3@7.5
Mil.btu/hr
|
3@8.75
Mil.btu/hr
|
3@10.75
Mil.btu/hr
|
| |
|
|
|
|
| |
Electric
Load
(Fan, Top Auger, Bottom Auger)*4 |
|
|
|
| |
Single
Phase, 230 V. |
N/A
|
N/A
|
N/A
|
| |
Three
Phase, 230 V. |
232
Amps
|
262
Amps
|
346
Amps
|
| |
Three
Phase, 460 V. |
152
Amps
|
173
Amps
|
202
Amps
|
| |
Three
Phase, 575 V. |
116
Amps
|
131
Amps
|
173
Amps
|
| |
Three
Phase, 380 V. 50Hz |
93
Amps
|
106
Amps
|
141
Amps
|
| |
|
|
|
|
| |
*1
- Capacities are wet bushels at input moisture content.
*2 - Grain discharged hot from the dryer will result in a final moisture
content of 15% after cooling in the bin.
*3 - Shortest possible height in ( ).
*4 - Maximum running load less auxiliary auger motors. |
|