TopDry
Autoflow Controls
The Autoflow Control System is exclusive to Maxim Top Dry and available
on all bin sizes from 18' to 36' diameter. Autoflow controls allow
operation in automatic batch mode or continuous flow mode. In batch
mode the Autoflow controls fill, dry and dump each batch automatically.
During operation in continuous flow mode, the dryest one-third of
the grain in the drying chamber is dumped and replaced with wet
grain. The drying chamber is never completely empty and the wetter
grain is always exposed to the higher temperature air.
|
  |

TopDry
Sidewall and Roofs
--------------------
TopDry Bin Access
--------------------
TopDry Floors
--------------------
TopDry Fans and Heaters
--------------------
TopDry Controls
--------------------
Top Dry Specifications

Autoflow
control boxes can be installed in a separate location from the drying
bin. This can help prevent dryer controls from being tampered with
or vandalized. Autoflow also offers an optional "Watchdog"
software package that allows all dryer operation to be monitored
remotely through a personal computer.

Autoflow
is totally microprocessor based (no moving parts) and is completely
driven by easily upgradeable software.
|
| |
This results in higher drying rates and more consistent moisture removal throughout. Autoflow features automatic shutdown in the event of fill switch failure
or empty wet supply, plenum high temperature protection, auger fill
delay and automatic or adjustable staged starting of fans and heaters.
The Autoflow monitors fan and heater conditions (8 total) indicating
which unit to shut down in the event of a malfunction, controls
multiple auger systems for installations without a wet hopper tank,
and automatically closes chutes in the event of a power loss. Autoflow
includes four sensors for grain moisture averaging (more sensors
yield better accuracy), motor starters for fill systems, batch counter,
reliable rotary fill switches (power paks mounted externally for
easier service) and has a 25 memory recall to keep track of unit shutdown including dates and times.
|
|

|
|