GSI International GSI
Home | About GSI | Sales & Support
Competitor Dryers--|--Network Dryers --|--Tower Dryers --|--Process Dryers --|--TopDry--|--Fans and Heaters
--> Home > Drying Systems > TopDry System > TopDry Batch Drying Specifications
TopDry Batch Drying Specifications
Bin Specifications | Batch Series Drying Rates | AutoFlow Series Drying Rates
 

Shelled Corn
(U.S. Measurements)

 
BATCH SERIES
21' Diameter
1 Fan
24' Diameter
1 Fan
30' Diameter
1 Fan
 
Fan and Heater Unit(s)
Plenum Temperature F¼
Moisture Content Wet Basis
Bu/Hr
Batch Time (hrs)
Bu/Hr
Batch Time (hrs)
Bu/Hr
Batch Time (hrs)
 
15 HP
36" Fan
3.5 mBTU/Hr
140
20%
25%
30%
357
226
141
2.1
3.3
5.2
398
252
157
2.5
3.8
6.1
461
292
182
3.3
5.1
8.2
  160 20%
25%
30%
426
270
168
1.8
2.7
4.4
474
300
187
2.0
3.2
5.2
550
348
218
2.8
4.4
6.8
  180 20%
25%
30%
545
345
215
1.4
2.1
3.4
607
384
240
1.6
2.6
4.0
* 677
* 429
* 268
* 2.4
* 3.7
* 6.0
 
 
15 HP
40" Fan
6.25 mBTU/Hr
140
20%
25%
30%
486
308
192
2.0
3.1
4.9
562
356
222
2.7
4.2
6.7
  160 20%
25%
30%
    580
367
230
1.6
2.6
4.2
670
425
265
2.2
3.5
5.6
  180 20%
25%
30%
    742
470
294
1.3
2.0
3.3
858
543
339
1.8
2.7
4.4
 
  30 HP
42" Fan
10.25 mBTU/Hr
140
20%
25%
30%
638
405
253
2.4
3.6
5.9
  160 20%
25%
30%
        762
482
302
2.0
3.1
4.9
  180 20%
25%
30%
        975
618
386
1.5
2.4
3.9
 
 
40 HP
42" Fan
10.25 mBTU/Hr
140
20%
25%
30%
726
460
287
2.1
3.3
5.2
  160 20%
25%
30%
        867
549
343
1.8
2.7
4.4
  180 20%
25%
30%
        1110
702
439
1.4
2.1
3.4

 

 
BATCH SERIES
30' Diameter
2 Fan
36' Diameter
1 Fan
36' Diameter
2 Fan
 
Fan and Heater Unit(s)
Plenum Temperature F¼
Moisture Content Wet Basis
Bu/Hr
Batch Time (hrs)
Bu/Hr
Batch Time (hrs)
Bu/Hr
Batch Time (hrs)
 
15 HP
36" Fan
3.5 mBTU/Hr
140
20%
25%
30%
728
461
288
1.9
3.3
5.2
521
330
206
4.1
6.5
10.4
841
533
333
2.6
4.0
6.5
  160 20%
25%
30%
869
550
344
1.8
2.7
4.4
622
394
246
3.4
5.4
8.7
1004
636
397
2.1
3.4
5.4
  180 20%
25%
30%
1112
704
440
1.4
2.1
3.4
* 694
* 440
* 274
* 3.4
* 5.2
* 8.3
1284
814
508
1.6
2.7
4.2
 
 
15 HP
40" Fan
6.25 mBTU/Hr
140
20%
25%
30%
650
411
257
3.3
5.2
8.4
1022
647
404
2.1
3.3
5.3
  160 20%
25%
30%
    775
491
306
2.8
4.4
7.1
1219
772
482
1.8
2.8
4.5
  180 20%
25%
30%
    * 890
* 564
* 352
* 2.6
* 4.1
* 6.5
1560
988
617
1.4
2.2
3.5
 
  30 HP
42" Fan
10.25 mBTU/Hr
140
20%
25%
30%
717
454
284
2.9
4.7
7.5
1142
723
452
1.9
2.9
4.7
  160 20%
25%
30%
    856
542
338
2.5
4.0
6.4
1363
863
539
1.5
2.5
4.0
  180 20%
25%
30%
    1095
694
433
2.0
3.1
4.9
1744
1105
690
1.3
2.0
3.2
 
 
40 HP
42" Fan
10.25 mBTU/Hr
140
20%
25%
30%
810
513
320
2.7
4.2
6.7
   
  160 20%
25%
30%
    966
612
382
2.2
3.5
5.6
   
  180 20%
25%
30%
    1236
783
489
1.8
2.7
4.4
   
 


* Insufficient burner BTU's for 45 degree F ambient temperature.

Capacities assume 1/4 cfm cooling rate.
Est. at ambient temp 45 deg. F, rel, humidity 65% .
Ratings exclude loading time.

Use only as a guide - capacities will vary with conditions.
Specifications subject to change without notice.

 


TopDry Sidewall and Roofs | TopDry Access | TopDry Floors | TopDry Controls
Bin Specifications | Batch Series Drying Rates | AutoFlow Series Drying Rates

Competitor Dryers | Network Dryers
Tower Dryers | Process Dryers | TopDry | Fans and Heaters

Grain Storage | Grain Drying and Conditioning | Material Handling
Home | About GSI | Sales & Support | FAQ's