X-STREAM™ Series Dryers Specifications
GSI offers several models of the Vision X-STREAM™ Series Dryers to meet your
specific drying capacity requirements. The easy to operate network
controls, which can be mounted on site or remotely, offer a great
deal of flexibility and convenience to installations large and small. |
| |
 |
 |
 |
| |
X-STREAM™ 1200 |
 |
 |
| |
X-STREAM™ 1200S |
X-STREAM™ 2300 |
X-STREAM™ 3400 |
 |
 |
 |
 |
 |
| |
Drying
Capacity Shelled Corn *1 ------ X-STREAM™ 1200 Models |
| |
Model
Numbers |
1220
|
1222
|
1226
|
| |
Dry
and Cool 25% to 15% |
345
BPH
|
395
BPH
|
450
BPH
|
| |
Dry
and Cool 20% to 15% |
560
BPH
|
640
BPH
|
725
BPH
|
| |
Full
Heat 30% to 15% *2 |
436
BPH
|
485
BPH
|
545
BPH
|
| |
Full
Heat 25% to 15% *2 |
590
BPH
|
650
BPH
|
730
BPH
|
| |
Full
Heat 20% to 15% *2 |
950
BPH
|
1055
BPH
|
1180
BPH
|
| |
|
|
|
|
| |
Grain
Columns |
14" x 20' Long
|
14" x 22' Long
|
14" x 26' Long
|
| |
Total
Holding Capacity |
544
Bu
|
599
Bu
|
708
Bu
|
| |
Grain
Column Holding Capacity |
470
Bu
|
517
Bu
|
611
Bu
|
| |
Top
Auger (Loading) |
8",
7.5 HP
|
8",
7.5 HP
|
8",
10 HP
|
| |
Capacity |
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Meter
Roll Drive |
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
| |
Maximum
Capacity |
2800
BPH
|
3080
BPH
|
3640
BPH
|
| |
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
33'-11"
|
35'-11"
|
39'-11"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
Transport
Weight
(Less Transport Kit) |
9,800
lbs.
(approx)
|
10,500
lbs.
(approx)
|
12.000
lbs.
(approx)
|
| |
Installed
Length |
27'-2"
|
29'-2"
|
33'-2"
|
| |
Installed
Width |
8'
|
8'
|
8'
|
| |
Installed
Height
(Excluding Foundation Supports) |
14'-6"
|
14'-6"
|
14'-6"
|
| |
|
|
|
|
| |
Fans:
1 PH |
1@15
HP, 40"
|
N/A
|
N/A
|
| |
|
1@10-12
HP, 28"
|
N/A
|
N/A
|
| |
Fans:
3 PH |
1@15
HP, 42"
|
1@20
HP, 42"
|
1@25
HP, 42"
|
| |
|
1@10-12
HP, 28"
|
1@10-12
HP, 28"
|
1@10-12
HP, 28"
|
| |
Heaters
(Max. BTU) |
1@5.5
Mil.btu/hr
|
1@6.75
Mil.btu/hr
|
1@7.5
Mil.btu/hr
|
| |
|
1@3.0
Mil.btu/hr
|
1@3.0
Mil.btu/hr
|
1@3.0
Mil.btu/hr
|
| |
|
|
|
|
| |
Electric
Load
(Fan, Top Auger, Bottom Auger)*4 |
|
|
|
| |
Single
Phase, 230 V. |
172
Amps
|
N/A
|
N/A
|
| |
Three
Phase, 230 V. |
112
Amps
|
126
Amps
|
150
Amps
|
| |
Three
Phase, 380 V. |
70
Amps
|
75
Amps
|
90
Amps
|
| |
Three
Phase, 460 V. |
57
Amps
|
63
Amps
|
75
Amps
|
| |
Three
Phase, 575 V. |
47
Amps
|
52
Amps
|
61
Amps
|
 |
 |
 |
 |
 |
| |
Drying
Capacity Shelled Corn *1 ------ X-STREAM™ 1200S Models |
| |
Model
Numbers |
1220S
|
1222S
|
1226S
|
| |
Dry
and Cool 25% to 15%
(Staged Batch)
|
395
BPH
|
430
BPH
|
530
BPH
|
| |
Dry
and Cool 20% to 15%
(Staged Batch) |
520
BPH
|
565
BPH
|
700
BPH
|
| |
Dry
and Cool 25% to 15% |
280
BPH
|
300
BPH
|
375
BPH
|
| |
Dry
and Cool 20% to 15% |
445
BPH
|
485
BPH
|
600
BPH
|
| |
Full
Heat 30% to 15% *2 |
455
BPH
|
495
BPH
|
620
BPH
|
| |
Full
Heat 25% to 15% *2 |
615
BPH
|
670
BPH
|
820
BPH
|
| |
Full
Heat 20% to 15% *2 |
990
BPH
|
1080
BPH
|
1330
BPH
|
| |
|
|
|
|
| |
Basic
Construction |
1
Module
|
1
Module
|
1
Module
|
| |
|
2
Stages
|
2
Stages
|
2
Stages
|
| |
|
|
|
|
| |
Grain
Columns |
14" x 20'
Long
|
14" x 22'
Long
|
14" x 26'
Long
|
| |
Total
Holding Capacity |
544
Bu
|
599
Bu
|
708
Bu
|
| |
Grain
Column Holding Capacity |
470
Bu
|
517
Bu
|
611
Bu
|
| |
Top
Auger (Loading) |
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Capacity |
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
7.5
HP
|
7.5 HP
|
10 HP
|
| |
Meter
Roll Drive |
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
| |
Maximum
Capacity |
2800
BPH
|
3080
BPH
|
3640
BPH
|
| |
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
33'-11"
|
35'-11"
|
39'-11"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
|
|
|
|
| |
Installed
Length |
27'-2"
|
30'-2"
|
33'-2"
|
| |
Installed
Width |
8'-
8"
|
8'-
8"
|
8'-
8"
|
| |
Installed
Height
(Excluding Foundation Supports) |
14'-6"
|
14'-6"
|
14'-6"
|
| |
|
|
|
|
| |
Fans:
1 PH |
2@15
HP, 36"
|
2@15
HP, 36"
|
N/A
|
| |
Fans:
3 PH |
2@15
HP, 36"
|
2@15
HP, 36"
|
2@25
HP, 40"
|
| |
Heaters
(Max. BTU) |
2@4.5
Mil.btu/hr.
|
2@4.5
Mil.btu/hr.
|
2@6.75
Mil.btu/hr.
|
| |
|
|
|
|
| |
Electric
Load
(Fan, Top Auger, Bottom Auger)*4 |
|
|
|
| |
Single
Phase, 230 V. |
186
Amps
|
186
Amps
|
N/A
|
| |
Three
Phase, 230 V. |
118
Amps
|
118
Amps
|
180
Amps
|
| |
Three
Phase, 380 V. |
80
Amps
|
80
Amps
|
115
Amps
|
| |
Three
Phase, 460 V. |
60
Amps
|
60
Amps
|
90
Amps
|
| |
Three
Phase, 575 V. |
48
Amps
|
48
Amps
|
72
Amps
|
 |
 |
 |
 |
 |
| |
Drying
Capacity Shelled Corn *1 ------ X-STREAM™ 2300 Models |
| |
Model
Numbers |
2320
|
2322
|
2326
|
| |
Dry
and Cool 25% to 15% |
850
BPH
|
930
BPH
|
1130
BPH
|
| |
Dry
and Cool 20% to 15% |
1375
BPH
|
1500
BPH
|
1835
BPH
|
| |
Full
Heat 30% to 15% *2 |
925
BPH
|
1010
BPH
|
1200
BPH
|
| |
Full
Heat 25% to 15% *2 |
1245
BPH
|
1355
BPH
|
1670
BPH
|
| |
Full
Heat 20% to 15% *2 |
2010
BPH
|
2195
BPH
|
2700
BPH
|
| |
|
|
|
|
| |
Basic
Construction |
2
Module
|
2
Module
|
2
Module
|
| |
|
4
Stages
|
4
Stages
|
4
Stages
|
| |
|
|
|
|
| |
Grain
Columns |
14" x 20'
Long
|
14" x 22'
Long
|
14" x 26'
Long
|
| |
Total
Holding Capacity |
1044
Bu
|
1149
Bu
|
1304
Bu
|
| |
Grain
Column Holding Capacity |
970
Bu
|
1067
Bu
|
1261
Bu
|
| |
Top
Auger (Loading) |
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Capacity |
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
7.5
HP
|
7.5 HP
|
10 HP
|
| |
Meter
Roll Drive |
SCR,
3/4 HP
|
SCR,
3/4 HP
|
SCR,
3/4 HP
|
| |
Maximum
Capacity |
2800
BPH
|
3080
BPH
|
3640
BPH
|
| |
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
33'-11"
|
35'-11"
|
39'-11"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
|
|
|
|
| |
Installed
Length |
29'-10"
|
31'-10"
|
35'-10"
|
| |
Installed
Width |
8'-
8"
|
8'-
8"
|
8'-
8"
|
| |
Installed
Height
(Excluding Foundation Supports) |
25'-11"
|
25'-11"
|
25'-11"
|
| |
|
|
|
|
| |
Fans:
1 PH |
N/A
|
N/A
|
N/A
|
| |
|
N/A
|
N/A
|
N/A
|
| |
Fans:
3 PH |
1@25
HP, 42"
|
1@30
HP, 42"
|
1@40
HP, 42"
|
| |
|
2@15
HP, 36"
|
2@15
HP, 36"
|
2@25
HP, 40"
|
| |
Heaters
(Max. BTU) |
1@7.5
Mil.btu/hr.
|
1@8.75
Mil.btu/hr.
|
1@10.75
Mil.btu/hr.
|
| |
|
2@4.5
Mil.btu/hr.
|
2@4.5
Mil.btu/hr.
|
2@6.75
Mil.btu/hr.
|
| |
|
|
|
|
| |
Electric
Load
(Fan, Top Auger, Bottom Auger)*4 |
|
|
|
| |
Single
Phase, 230 V. |
N/A
|
N/A
|
N/A
|
| |
Three
Phase, 230 V. |
182
Amps
|
192
Amps
|
278
Amps
|
| |
Three
Phase, 380 V. |
122
Amps
|
129
Amps
|
172
Amps
|
| |
Three
Phase, 460 V. |
91
Amps
|
96
Amps
|
139
Amps
|
| |
Three
Phase, 575 V. |
74
Amps
|
78
Amps
|
112
Amps
|
 |
 |
 |
 |
 |
| |
Drying
Capacity Shelled Corn *1 ------ X-STREAM™ 3400 Models |
| |
Model
Numbers |
3420
|
3422
|
3426
|
| |
Dry
and Cool 25% to 15% |
1120
BPH
|
1250
BPH
|
1520
BPH
|
| |
Dry
and Cool 20% to 15% |
1800
BPH
|
2015
BPH
|
2445
BPH
|
| |
Full
Heat 30% to 15% *2 |
1400
BPH
|
1515
BPH
|
1825
BPH
|
| |
Full
Heat 25% to 15% *2 |
1825
BPH
|
2040
BPH
|
2475
BPH
|
| |
Full
Heat 20% to 15% *2 |
2950
BPH
|
3300
BPH
|
4000
BPH
|
| |
|
|
|
|
| |
Basic
Construction |
3
Modules
|
3
Modules
|
3
Modules
|
| |
|
6
Stages
|
6
Stages
|
6
Stages
|
| |
|
|
|
|
| |
Grain
Columns |
14"
x 20"
Long
|
14"
x 22"
Long
|
14"
x 26"
Long
|
| |
Total
Holding Capacity |
1534
Bu
|
1688
Bu
|
1995
Bu
|
| |
Grain
Column Holding Capacity |
1460
Bu
|
1606
Bu
|
1898
Bu
|
| |
Top
Auger (Loading) |
7.5
HP
|
7.5
HP
|
10
HP
|
| |
Capacity |
3800
BPH
|
3800
BPH
|
3800
BPH
|
| |
Bottom
Auger (Unloading) |
7.5
HP
|
7.5 HP
|
10 HP
|
| |
Meter
Roll Drive |
SCR
3/4 HP
|
SCR
3/4 HP
|
SCR
3/4 HP
|
| |
Maximum
Capacity |
2800
BPH
|
3080
BPH
|
3640
BPH
|
| |
|
|
|
|
| |
Transport
Length
(Hitch to Discharge Auger) |
33'-11"
|
35'-11"
|
39'-11"
|
| |
Transport
Width |
8'
|
8'
|
8'
|
| |
Transport
Height *3 |
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
13'-5"
(11'-9")
|
| |
|
|
|
|
| |
Installed
Length |
29'-10"
|
31'-10"
|
35'-10"
|
| |
Installed
Width |
8'-
8"
|
8'-
8"
|
8'-
8"
|
| |
Installed
| |