GSI International GSI
Home | About GSI | Sales & Support
Competitor Dryers--|--Network Dryers --|--Tower Dryers --|--Process Dryers --|--TopDry--|--Fans and Heaters
--> Home > Drying Systems > X-Stream™ Series Dryers > X-STREAM™ Series Dryers
X-STREAM™ Series Dryers Specifications
GSI offers several models of the Vision X-STREAM™ Series Dryers to meet your specific drying capacity requirements. The easy to operate network controls, which can be mounted on site or remotely, offer a great deal of flexibility and convenience to installations large and small.

  X-STREAM™ 1200 X-STREAM™ 2300 X-STREAM™ 3400
  X-STREAM™ 1200
X-STREAM™ 1200S
  X-STREAM™ 1200S X-STREAM™ 2300 X-STREAM™ 3400
  Drying Capacity Shelled Corn *1 ------ X-STREAM™ 1200 Models
  Model Numbers
1220
1222
1226
  Dry and Cool 25% to 15%
345 BPH
395 BPH
450 BPH
  Dry and Cool 20% to 15%
560 BPH
640 BPH
725 BPH
  Full Heat 30% to 15% *2
436 BPH
485 BPH
545 BPH
  Full Heat 25% to 15% *2
590 BPH
650 BPH
730 BPH
  Full Heat 20% to 15% *2
950 BPH
1055 BPH
1180 BPH
         
  Grain Columns
14" x 20' Long
14" x 22' Long
14" x 26' Long
  Total Holding Capacity
544 Bu
599 Bu
708 Bu
  Grain Column Holding Capacity
470 Bu
517 Bu
611 Bu
  Top Auger (Loading)
8", 7.5 HP
8", 7.5 HP
8", 10 HP
  Capacity
3800 BPH
3800 BPH
3800 BPH
  Bottom Auger (Unloading)
7.5 HP
7.5 HP
10 HP
  Meter Roll Drive
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
  Maximum Capacity
2800 BPH
3080 BPH
3640 BPH
         
  Transport Length
(Hitch to Discharge Auger)
33'-11"
35'-11"
39'-11"
  Transport Width
8'
8'
8'
  Transport Height *3
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
  Transport Weight
(Less Transport Kit)
9,800 lbs.
(approx)
10,500 lbs.
(approx)
12.000 lbs.
(approx)
  Installed Length
27'-2"
29'-2"
33'-2"
  Installed Width
8'
8'
8'
  Installed Height
(Excluding Foundation Supports)
14'-6"
14'-6"
14'-6"
         
  Fans: 1 PH
1@15 HP, 40"
N/A
N/A
   
1@10-12 HP, 28"
N/A
N/A
  Fans: 3 PH
1@15 HP, 42"
1@20 HP, 42"
1@25 HP, 42"
   
1@10-12 HP, 28"
1@10-12 HP, 28"
1@10-12 HP, 28"
  Heaters (Max. BTU)
1@5.5 Mil.btu/hr
1@6.75 Mil.btu/hr
1@7.5 Mil.btu/hr
   
1@3.0 Mil.btu/hr
1@3.0 Mil.btu/hr
1@3.0 Mil.btu/hr
         
  Electric Load
(Fan, Top Auger, Bottom Auger)*4
     
  Single Phase, 230 V.
172 Amps
N/A
N/A
  Three Phase, 230 V.
112 Amps
126 Amps
150 Amps
  Three Phase, 380 V.
70 Amps
75 Amps
90 Amps
  Three Phase, 460 V.
57 Amps
63 Amps
75 Amps
  Three Phase, 575 V.
47 Amps
52 Amps
61 Amps
  Drying Capacity Shelled Corn *1 ------ X-STREAM™ 1200S Models
 
Model Numbers
1220S
1222S
1226S
 
Dry and Cool 25% to 15%
(Staged Batch)
395 BPH
430 BPH
530 BPH
 
Dry and Cool 20% to 15%
(Staged Batch)
520 BPH
565 BPH
700 BPH
 
Dry and Cool 25% to 15%
280 BPH
300 BPH
375 BPH
 
Dry and Cool 20% to 15%
445 BPH
485 BPH
600 BPH
 
Full Heat 30% to 15% *2
455 BPH
495 BPH
620 BPH
 
Full Heat 25% to 15% *2
615 BPH
670 BPH
820 BPH
 
Full Heat 20% to 15% *2
990 BPH
1080 BPH
1330 BPH
 
     
 
Basic Construction
1 Module
1 Module
1 Module
 
2 Stages
2 Stages
2 Stages
 
     
 
Grain Columns
14" x 20'
Long
14" x 22'
Long
14" x 26'
Long
 
Total Holding Capacity
544 Bu
599 Bu
708 Bu
 
Grain Column Holding Capacity
470 Bu
517 Bu
611 Bu
 
Top Auger (Loading)
7.5 HP
7.5 HP
10 HP
 
Capacity
3800 BPH
3800 BPH
3800 BPH
 
Bottom Auger (Unloading)
7.5 HP
7.5 HP
10 HP
 
Meter Roll Drive
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
 
Maximum Capacity
2800 BPH
3080 BPH
3640 BPH
 
     
 
Transport Length
(Hitch to Discharge Auger)
33'-11"
35'-11"
39'-11"
 
Transport Width
8'
8'
8'
 
Transport Height *3
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
 
     
 
Installed Length
27'-2"
30'-2"
33'-2"
 
Installed Width
8'- 8"
8'- 8"
8'- 8"
 
Installed Height
(Excluding Foundation Supports)
14'-6"
14'-6"
14'-6"
 
     
 
Fans: 1 PH
2@15 HP, 36"
2@15 HP, 36"
N/A
 
Fans: 3 PH
2@15 HP, 36"
2@15 HP, 36"
2@25 HP, 40"
 
Heaters (Max. BTU)
2@4.5 Mil.btu/hr.
2@4.5 Mil.btu/hr.
2@6.75 Mil.btu/hr.
 
     
 
Electric Load
(Fan, Top Auger, Bottom Auger)*4
     
 
Single Phase, 230 V.
186 Amps
186 Amps
N/A
 
Three Phase, 230 V.
118 Amps
118 Amps
180 Amps
 
Three Phase, 380 V.
80 Amps
80 Amps
115 Amps
 
Three Phase, 460 V.
60 Amps
60 Amps
90 Amps
 
Three Phase, 575 V.
48 Amps
48 Amps
72 Amps
  Drying Capacity Shelled Corn *1 ------ X-STREAM™ 2300 Models
  Model Numbers
2320
2322
2326
  Dry and Cool 25% to 15%
850 BPH
930 BPH
1130 BPH
  Dry and Cool 20% to 15%
1375 BPH
1500 BPH
1835 BPH
  Full Heat 30% to 15% *2
925 BPH
1010 BPH
1200 BPH
  Full Heat 25% to 15% *2
1245 BPH
1355 BPH
1670 BPH
  Full Heat 20% to 15% *2
2010 BPH
2195 BPH
2700 BPH
         
  Basic Construction
2 Module
2 Module
2 Module
   
4 Stages
4 Stages
4 Stages
         
  Grain Columns
14" x 20'
Long
14" x 22'
Long
14" x 26'
Long
  Total Holding Capacity
1044 Bu
1149 Bu
1304 Bu
  Grain Column Holding Capacity
970 Bu
1067 Bu
1261 Bu
  Top Auger (Loading)
7.5 HP
7.5 HP
10 HP
  Capacity
3800 BPH
3800 BPH
3800 BPH
  Bottom Auger (Unloading)
7.5 HP
7.5 HP
10 HP
  Meter Roll Drive
SCR, 3/4 HP
SCR, 3/4 HP
SCR, 3/4 HP
  Maximum Capacity
2800 BPH
3080 BPH
3640 BPH
         
  Transport Length
(Hitch to Discharge Auger)
33'-11"
35'-11"
39'-11"
  Transport Width
8'
8'
8'
  Transport Height *3
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
         
  Installed Length
29'-10"
31'-10"
35'-10"
  Installed Width
8'- 8"
8'- 8"
8'- 8"
  Installed Height
(Excluding Foundation Supports)
25'-11"
25'-11"
25'-11"
         
  Fans: 1 PH
N/A
N/A
N/A
   
N/A
N/A
N/A
  Fans: 3 PH
1@25 HP, 42"
1@30 HP, 42"
1@40 HP, 42"
   
2@15 HP, 36"
2@15 HP, 36"
2@25 HP, 40"
  Heaters (Max. BTU)
1@7.5 Mil.btu/hr.
1@8.75 Mil.btu/hr.
1@10.75 Mil.btu/hr.
   
2@4.5 Mil.btu/hr.
2@4.5 Mil.btu/hr.
2@6.75 Mil.btu/hr.
         
  Electric Load
(Fan, Top Auger, Bottom Auger)*4
     
  Single Phase, 230 V.
N/A
N/A
N/A
  Three Phase, 230 V.
182 Amps
192 Amps
278 Amps
  Three Phase, 380 V.
122 Amps
129 Amps
172 Amps
  Three Phase, 460 V.
91 Amps
96 Amps
139 Amps
  Three Phase, 575 V.
74 Amps
78 Amps
112 Amps
  Drying Capacity Shelled Corn *1 ------ X-STREAM™ 3400 Models
  Model Numbers
3420
3422
3426
  Dry and Cool 25% to 15%
1120 BPH
1250 BPH
1520 BPH
  Dry and Cool 20% to 15%
1800 BPH
2015 BPH
2445 BPH
  Full Heat 30% to 15% *2
1400 BPH
1515 BPH
1825 BPH
  Full Heat 25% to 15% *2
1825 BPH
2040 BPH
2475 BPH
  Full Heat 20% to 15% *2
2950 BPH
3300 BPH
4000 BPH
         
  Basic Construction
3 Modules
3 Modules
3 Modules
   
6 Stages
6 Stages
6 Stages
         
  Grain Columns
14" x 20"
Long
14" x 22"
Long
14" x 26"
Long
  Total Holding Capacity
1534 Bu
1688 Bu
1995 Bu
  Grain Column Holding Capacity
1460 Bu
1606 Bu
1898 Bu
  Top Auger (Loading)
7.5 HP
7.5 HP
10 HP
  Capacity
3800 BPH
3800 BPH
3800 BPH
  Bottom Auger (Unloading)
7.5 HP
7.5 HP
10 HP
  Meter Roll Drive
SCR 3/4 HP
SCR 3/4 HP
SCR 3/4 HP
  Maximum Capacity
2800 BPH
3080 BPH
3640 BPH
         
  Transport Length
(Hitch to Discharge Auger)
33'-11"
35'-11"
39'-11"
  Transport Width
8'
8'
8'
  Transport Height *3
13'-5" (11'-9")
13'-5" (11'-9")
13'-5" (11'-9")
         
  Installed Length
29'-10"
31'-10"
35'-10"
  Installed Width
8'- 8"
8'- 8"
8'- 8"
  Installed