1600 Model Mixed Flow Dryers
| 1608 | 1612 | 1614 | 1616 | 1618 | 1620 | 1624 | |
|---|---|---|---|---|---|---|---|
| Drying Capacity (BPH), Shelled Corn1 | |||||||
| Dry and Cool 30% to 15% | 340 | 470 | 700 | 750 | 800 | 910 | 1,180 |
| Dry and Cool 25% to 15% | 440 | 730 | 900 | 960 | 1,030 | 1,160 | 1,500 |
| Dry and Cool 20% to 15% | 710 | 1,180 | 1,450 | 1,550 | 1,670 | 1,890 | 2,440 |
| Full Heat 30% to 15%2 | 590 | 890 | 1,060 | 1,190 | 1,340 | 1,470 | 1,800 |
| Full Heat 25% to 15%2 | 710 | 1,060 | 1,270 | 1,430 | 1,600 | 1,770 | 2,170 |
| Full Heat 20% to 15%2 | 1,060 | 1,580 | 1,890 | 2,130 | 2,380 | 2,630 | 3,220 |
| Total Holding Cap. (Auger Fill) | 1,037 | 1,405 | 1,589 | 1,773 | 1,957 | 2,141 | 2,911 |
| Total Holding Cap. (Gravity Fill) | 1,048 | 1,416 | 1,600 | 1,784 | 1,968 | 2,152 | 2,922 |
| Grain Column Holding Cap. (bu.) | 736 | 1,104 | 1,288 | 1,472 | 1,656 | 1,840 | 2,208 |
| Top Auger (Loading) | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP |
| Discharge Conveyor (Unloading) | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP |
| Meter Roll Drive | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP |
| Installed Length | 27’9″ | 27’9″ | 27’9″ | 27’9″ | 27’9″ | 27’9″ | 27’9″ |
| Installed Width | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ |
| Installed Height (Auger) | 31’5″ | 39’5″ | 43’5″ | 47’5″ | 51’5″ | 55’5″ | 63’5″ |
| Installed Height (Gravity Fill) | 32’3″ | 40’3″ | 44’3″ | 48’3″ | 52’3″ | 56’3″ | 64’3″ |
| Heaters (Max BTU) (mmBTU) | 10.5 | 15 | 19.5 | 18 | 22.5 | 22.5 | 27 |
| Centrifugal Fans | (2) 15 HP* | (3) 15 HP* | (2) 30 HP & (1) 15 HP | (4) 15 HP* | (2) 30 HP & (2) 15 HP | (5) 15 HP* | (6) 15 HP* |
| Full Load Amps (Fan(s), load Auger, Discharge Conveyor)3 | |||||||
| Full Load Amps (Fan(s), load Auger, Discharge Conveyor)3 | |||||||
| Three Phase, 208 V. | 119 | 161 | 244 | 203 | 286 | 244 | 265 |
1 – Capacities listed are wet bushels, for mature unfrozen #2 yellow shelled dent corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain’s physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.
2 – Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin.
3 – Full Load Amps: Fan(s) & Dryer Load & Unload motor name plate amperages + 5 for control & VFD load.
* – Available in single phase.
2400 Model Mixed Flow Dryers
| 2408 | 2412 | 2414 | 2416 | 2418 | 2420 | 2424 | |
|---|---|---|---|---|---|---|---|
| Drying Capacity (BPH), Shelled Corn1 | |||||||
| Dry and Cool 30% to 15% | 490 | 810 | 960 | 1,070 | 1,120 | 1,300 | 1,580 |
| Dry and Cool 25% to 15% | 630 | 1,040 | 1,230 | 1,360 | 1,440 | 1,660 | 2,030 |
| Dry and Cool 20% to 15% | 1,020 | 1,690 | 2,000 | 2,220 | 2,340 | 2,700 | 3,300 |
| Full Heat 30% to 15%2 | 850 | 1,270 | 1,460 | 1,730 | 1,880 | 2,110 | 2,480 |
| Full Heat 25% to 15%2 | 1,020 | 1,520 | 1,750 | 2,080 | 2,260 | 2,530 | 2,980 |
| Full Heat 20% to 15%2 | 1,510 | 2,260 | 2,610 | 3,090 | 3,360 | 3,770 | 4,440 |
| Total Holding Cap. (Auger Fill) | 1,564 | 2,116 | 2,392 | 2,668 | 3,043 | 3,453 | 4,013 |
| Total Holding Cap. (GRAVITY Fill) | 1,611 | 2,163 | 2,439 | 2,715 | 2,991 | 3,267 | 4,060 |
| Grain Column Holding Cap. (BU.) | 1,104 | 1,656 | 1,932 | 2,208 | 2,484 | 2,760 | 3,312 |
| Top Auger (Loading) | 10 HP | 10 HP | 10 HP | 10 HP | 10 HP | 10 HP | 10 HP |
| Discharge Conveyor (Unloading) | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP |
| Meter Roll Drive | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP |
| Installed Length | 35’9″ | 35’9″ | 35’9″ | 35’9″ | 35’9″ | 35’9″ | 35’9″ |
| Installed Width | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ |
| Installed Height (Auger) | 31’5″ | 39’5″ | 43’5″ | 47’5″ | 51’5″ | 55’5″ | 63’5″ |
| Installed Height (Gravity Fill) | 35’0″ | 43’0″ | 47’0″ | 51’0″ | 55’0″ | 59’0″ | 67’0″ |
| Heaters (Max BTU) (mmBTU) | 12.75 | 19.5 | 23.5 | 27 | 31 | 33.8 | 40.6 |
| Centrifugal Fans | (2) 30 HP | (3) 30 HP | (2) 40 HP & (1) 30 HP | (4) 30 HP | (2) 40 HP & (2) 30 HP | (5) 30 HP | (6) 40 HP |
| Full Load Amps (Fan(s), load Auger, Discharge Conveyor)3 | |||||||
| Full Load Amps (Fan(s), load Auger, Discharge Conveyor)3 | |||||||
| Three Phase, 208 V. | 216 | 300 | 355 | 383 | 438 | 466 | 480 |
| Three Phase, 230 V. | 206 | 285 | 338 | 364 | 416 | 443 | 455 |
| Three Phase, 460 V. | 99 | 137 | 162 | 174 | 199 | 212 | 232 |
| Three Phase, 575 V. | 79 | 109 | 130 | 140 | 160 | 170 | 183 |
1 – Capacities listed are wet bushels, for mature unfrozen #2 yellow shelled dent corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain’s physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.
2 – Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin.
3 – Full Load Amps: Fan(s) & Dryer Load & Unload motor name plate amperages + 5 for control & VFD load.
3200 Model Mixed Flow Dryers
| 3208 | 3212 | 3214 | 3216 | 3218 | 3220 | 3224 | |
|---|---|---|---|---|---|---|---|
| Drying Capacity (BPH), Shelled Corn1 | |||||||
| Dry and Cool 30% to 15% | 620 | 1,040 | 1,220 | 1,330 | 1,410 | 1,670 | 2,050 |
| Dry and Cool 25% to 15% | 800 | 1,330 | 1,560 | 1,710 | 1,800 | 2,130 | 2,620 |
| Dry and Cool 20% to 15% | 1,300 | 2,160 | 2,530 | 2,770 | 2,929 | 3,460 | 4,250 |
| Full Heat 30% to 15%2 | 1,080 | 1,620 | 1,830 | 2,170 | 2,370 | 2,700 | 3,200 |
| Full Heat 25% to 15%2 | 1,300 | 1,950 | 2,190 | 2,610 | 2,840 | 3,250 | 3,830 |
| Full Heat 20% to 15%2 | 1,930 | 2,900 | 3,260 | 3,890 | 4,230 | 4,830 | 5,710 |
| Total Holding Cap. (Auger Fill) | 2,092 | 2,828 | 3,196 | 3,564 | 3,932 | 4,300 | 5,156 |
| Total Holding Cap. (GRAVITY Fill) | 2,198 | 2,934 | 3,302 | 3,670 | 4,038 | 4,406 | 5,262 |
| Grain Column Holding Cap. (BU.) | 1,478 | 2,217 | 2,586 | 2,956 | 3,325 | 3,695 | 4,440 |
| Top Auger (Loading) | 15 HP | 15 HP | 15 HP | 15 HP | 15 HP | 15 HP | 15 HP |
| Discharge Conveyor (Unloading) | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP | 5 HP |
| Meter Roll Drive | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP | .75 HP |
| Installed Length | 43’9″ | 43’9″ | 43’9″ | 43’9″ | 43’9″ | 43’9″ | 43’9″ |
| Installed Width | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ | 9’2″ |
| Installed Height (Auger) | 31’5″ | 39’5″ | 43’5″ | 47’5″ | 51’5″ | 55’5″ | 63’5″ |
| Installed Height (Gravity Fill) | 37’10” | 45’10” | 49’10” | 53’10” | 57’10” | 61’10” | 69’10” |
| Heaters (Max BTU) (mmBTU) | 14.75 | 23.5 | 26.5 | 35 | 38 | 43.8 | 52.5 |
| Centrifugal Fans | (2) 40 HP | (3) 40 HP | (2) 50HP & (1) 40 HP | (4) 40 HP | (2) 50 HP & (2) 40 HP | (5) 40 HP | (6) 40 HP |
| Full Load Amps (Fan(s), load Auger, Discharge Conveyor)3 | |||||||
| Full Load Amps (Fan(s), load Auger, Discharge Conveyor)3 | |||||||
| Three Phase, 208 V. | 286 | 397 | 452 | 508 | 563 | 619 | 654 |
| Three Phase, 230 V. | 272 | 377 | 430 | 483 | 535 | 588 | 645 |
| Three Phase, 460 V. | 130 | 180 | 206 | 231 | 256 | 281 | 327 |
| Three Phase, 575 V. | 104 | 144 | 165 | 185 | 205 | 225 | 271 |
1 – Capacities listed are wet bushels, for mature unfrozen #2 yellow shelled dent corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain’s physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.